Wire Gauge

Maximum Length

 

 

 

#22 gauge

450

feet

 

 

 

#20 gauge

700

feet

 

 

 

#18 gauge

1100

feet

 

 

 

#16 gauge

1750

feet

 

 

 

 

NOTE: The length of all wire runs combined must not exceed 2000 feet when unshielded quad conductor cable is used (1000 feet if shielded cable is used.)

If more than one keypad is wired to a run, then the above maximum lengths must be divided by the number of keypads on the run (i.e. the maximum length would be 225 feet if two keypads are wired on a #22 gauge run).

Setting the Keypad Address

To set the keypad's address, do the following:

1.Enter the address mode: Power-up (plug-in) the keypad. Within 60 seconds of system power-up, press and hold down the [1] and [3] keys at the same time for 3 seconds. (If unable to enter address mode, power-up and try again.)

The current keypad address will be displayed, and the cursor will be under the "tens" digit. If 10 seconds have passed with no key entry, the keypad automatically exits address mode. You must then power down, power-up and start address mode again. Note: The keypad will not enter address mode if the panel to which it is connected

is in programming mode.

2.Set the current address to "00": Press [0] to clear the current "tens" digit. The cursor will move to the "ones" digit position. Press [0] to clear the current "ones" digit. The cursor will move back to the "tens" digit position.

3.Enter the keypad's address: Enter the proper "tens" digit of the keypad's address. The cursor will move to the "ones" digit position. Enter the proper "ones" digit of the keypad's address.

Note that address "31" sets the keypad to the non-addressable mode.

4.Exit the address mode:

Press [*] to save the displayed address and exit address mode.

Note: If 10 seconds passes with no key entry, the keypad automatically exits address mode.

Viewing the Keypad Address

Press and hold down the [1] and [3] keys at the same time for about 3 seconds. The current address will be displayed. No key entry is allowed in this mode. Press any key to exit or wait 10 seconds to exit the viewing mode.

Powering Additional

Up to five (5) 6139 keypads can be powered from the auxiliary power output provided

Keypads

that the 750mA rating is not exceeded. The backup battery will supply power to these

 

keypads in the event that AC power is lost.

 

Additional keypads, up to the system maximum of 16, can be connected to the

 

system by using a regulated, 12VDC power supply (e.g., 488-12 supplies 12V,

 

500mA). Use a UL Listed, battery-backed supply for UL installations.

 

Connect additional keypads as shown below, using the keypad wire colors shown.

 

Make sure to observe the current ratings for the power supply used.

SUPPLEMENTARY POWER SUPPLY

+ –

CONTROL

TERMINAL STRIP

AUX AUX. DATA DATA + – IN OUT

6 7 8 9

IMPORTANT

Common (Ð) of auxiliary power supply must be connected to (Ð) terminal 7 of the control panel.

TO KEYPAD RED WIRE

TO KEYPAD BLK WIRE

GRN WIRE

YEL WIRE

 

 

TO KEYPAD

TO KEYPAD

TO KEYPAD RED WIRE

TO KEYPAD BLK WIRE

GRN WIRE

YEL WIRE

TO KEYPAD

TO KEYPAD

IMPORTANT:

MAKE CONNECTIONS DIRECTLY TO SCREW TERMINALS AS SHOWN.

MAKE NO CONNECTION TO THE KEYPAD BLUE WIRE (IF PRESENT).

POWERING ADDITIONAL KEYPADS