8.The system will search for the next zone that does not have a serial number associated with it. If one is found, the prompt in step 5, along with the appropriate zone number, will be displayed. Follow steps 5 and 6 for the remaining zones.

After all zones have been displayed, whether enrolled or not, the "ENTER ZN NO." prompt will appear. Enter "00" to exit the Sequential mode and return to data field programming mode.

When you have finished programming all zones, test each using the system's TEST mode. Do not use the Transmitter ID Sniffer mode for this, as it will only check for transmission of one zone on a particular transmitter, NOT the zones assigned to each additional loop, and will NOT verify polling loop type.

RF SERIAL NUMBER CLEAR MODE (#93)

This mode may be used in the event that an undesired transmitter has been enrolled during sequential enrolling, causing each subsequent serial number to be assigned to an incorrect zone. Performing this operation will delete all RF serial numbers, leaving all other zone information intact. You may then return to Sequential mode to re-enroll wireless transmitters.

The RF Serial Number Clear mode will not delete polling loop serial numbers.

To clear all RF wireless serial numbers, do the following:

 

 

 

 

1.

Enter Programming mode [Installer Code] + 8 + 0 + 0 on an alpha

 

 

 

 

 

keypad. Enter RF Serial Number Clear mode by pressing #93. Press 0

 

 

 

 

 

repeatedly until the "CLEAR RF SERIAL #?" prompt is displayed as

 

 

 

 

 

follows:

 

 

 

 

2.

Enter "1" to clear all RF wireless serial numbers. The "ARE YOU SURE?"

 

CLEAR RF SERIAL#?

 

 

 

 

prompt is displayed as follows:

 

1 = YES, 0 = NO

0

 

 

 

 

 

 

 

 

 

 

3.

Enter "1" to clear all RF serial numbers. Re-enter the Sequential mode to

 

 

 

 

 

 

 

 

 

ARE YOU SURE?

 

 

 

 

 

 

enroll wireless transmitters.

 

1 = YES, 0 = NO

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ð 7 Ð

Page 121
Image 121
Guardian Technologies VISTA-40, N7001V2 installation instructions RF Serial Number Clear Mode #93, Clear RF SERIAL#?