Ground Start Module

Not intended for use in UL Listed applications.

Outputs 2 & 4: Operate, by default, as Fire and Silent Panic/Duress triggers respectively. These triggers may optionally be programmed to act as Arm and Ready status indicators when it is desired to use the 4146 keyswitch.

Output 2, 3, & 4 Rating: When Activated: 10Ð13.8 VDC through 5K ohms (2mA max).

When De-activated: 1k ohms to ground.

An optional 675 Ground Start module can be used for installations having telephone lines which require ground start instead of loop start operation to obtain dial tone from the telco central office.

If used, program field 1*46 must be set to "0" (factory default) and the 675 Ground Start Module must be connected to the panel's J7 connector trigger output 1, to auxiliary power, and to the "RING" side of the telephone line as shown in the diagram that follows.

Use the following procedure to determine which side of the telephone line is the "RING" side:

a.Connect the "+" lead of a DC voltmeter to earth ground, and the "Ð" lead to one side of the telephone line.

b.The wire which reads +50VDC is the "RING" side.

When the panel has a message to transmit to the central station, it will seize the line, go off hook, and then trigger the 675 module to connect the "RING" side of the telephone line to earth ground. The panel will cause the module to break the connection between "RING" and earth ground when a dial tone is obtained.

4142TR CABLE

J7 CONNECTOR

 

 

 

 

 

GROUND START

675

 

 

 

TRIGGER

 

 

 

BLUE

 

 

 

 

GROUND

 

 

 

 

 

 

 

 

 

 

 

 

START

 

 

 

 

 

 

 

MODULE

 

 

 

 

 

 

 

 

 

 

 

TO AUX. POWER

 

 

 

 

 

 

 

 

 

 

(CUT ORANGE

 

BLACK

 

TERM. 7

 

 

JUMPER)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO AUX. POWER

 

 

 

 

 

VIOLET

 

TERM. 6

 

 

 

 

 

 

(50mA CURRENT DRAW

 

 

 

 

 

 

 

 

 

BROWN

 

GREEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IF USED.

TO TELCO

TO EARTH

 

 

1. OUT 1 IS NO LONGER

RING

GROUND

 

 

 

USABLE FOR OPEN/CLOSE

 

 

 

 

 

 

 

(SEE FIELD 1*46).

2. OUT 2, 3, 4 CAN STILL BE USED TO PROVIDE ALARM STATUS INDICATIONS OR TO OPERATE A KEYSWITCH (SEE FIELD *15).

3. THE 675 IS NOT UL LISTED.

GROUND OUT 1

GROUND OUT 2

GROUND OUT 3

GROUND OUT 4

GRAY

YELLOW

WHITE

RED

GREEN

BROWN

BLUE

BLACK

N/U

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

GROUND START MODULE CONNECTIONS

Remote Keyswitch

If the keyswitch option is selected (field *15), the alarm trigger outputs 2Ð4 are

 

disabled.

 

An optional Remote Keyswitch can be used for remote arming and disarming of

 

the system. Note that keyswitch arming may only be used in one

 

partition.

 

If used, program field *15 must be set to the desired partition to enable the

 

keyswitch option, and the 4146 keyswitch's normally open momentary switch and

 

LEDs must be connected to Zone 7 and to the J7 connector trigger outputs

 

respectively. A 2k EOL resistor must be connected across the switch

 

regardless of whether or not zones 2Ð8 are selected to use EOL

 

resistors. See keyswitch wiring diagram on the next page.

 

Note that the system automatically assigns zone type 10 to zone 7 if a keyswitch

 

is used.

Ð 28 Ð