Guardian Technologies VISTA-40 Start Event Trouble Start ZN Type, RLY Voice DESCR? 0=NO 1=YES

Models: N7001V2 VISTA-40

1 122
Download 122 pages 53.89 Kb
Page 69
Image 69

Programming The Vim For

To program the system to trigger a relay upon an VIM fault, use the Relay

Relay Triggering On

Programming Menu (as described earlier) but enter the following values at the

Supervision Fault

appropriate prompts. When programmed, the relay activates upon VIM failure and

 

deactivates when the operation of the VIM is restored.

0 2 START EVENT

TROUBLE 3

02 START: ZN TYPE

Enter 3 (trouble) as the event code to start the relay action.

Enter the start zone type code 64 (VIM Fail).

 

Program the other Relay Programming prompts as you normally would.

Relay Voice Descriptors

For each of the 8 relays/X-10 modules used in the system, a voice descriptor can

 

be programmed. This descriptor will be annunciated by the phone module when

 

performing the #70 relay commands via telephone.

 

Each voice descriptor can consist of up to 3 words selected from the relay voice

 

descriptor vocabulary list shown below. Important: The index numbers from this

 

vocabulary list are to be used for relay voice descriptors only. For normal system

 

voice annunciation (e.g., alarms, troubles, status), use the highlighted words in

 

the alpha vocabulary list found in the alpha programming section.

RLY VOICE DESCR? 0=NO 1=YES

Press 1 to program voice descriptors for relays.

ENTER RELAY NO.

00=QUIT 01

01 ENTER DESC

d1

 

 

 

 

01 ENTER DESC

d2

 

 

 

 

01 ENTER DESC

d3

 

 

Enter the 2-digit relay/X-10 module number (01-08) for the relay desired, or enter 00 to quit relay voice descriptor programming mode. Press [*] to accept entry.

From the relay voice descriptor vocabulary list, enter the 3-digit index number for the first word of the relay descriptor phrase. Press [*] to accept entry.

From the relay voice descriptor vocabulary list, enter the 3-digit index number for the second word of the relay descriptor phrase. If second word is not desired, press 000. Press [*] to accept entry.

From the relay voice descriptor vocabulary list, enter the 3-digit index number for the third word of the relay descriptor phrase. If third word is not desired, press 000. Press [*] to accept entry.

The ENTER RELAY NO. prompt will appear. Enter the next relay number to be programmed, or enter 00 to quit.