Chime option for other partition during 2-way voice session.

 

 

¥

VIM text option for displaying voice mode text at the keypad.

 

 

¥

VIM AC loss option, when enabled, allows 2-way voice communication after AC

 

 

 

loss (recommended for installations where someone is on a life support device)

 

 

¥

The AUTO CALLBACK option, when enabled, allows callback to initiate 2-way

 

 

 

voice communication, otherwise Òlisten in to followÓ (event code 606) is sent at

 

 

 

end of alarm report.

Programming

¥

Device address as programmed at the keypad (01-15). Address 00 not

Information

For the

 

applicable. NOTE: Address 04 is reserved for the 4285 phone module.

6139AV

Keypad

¥

Device type "8".

 

 

¥

Voice keypad number (01Ð16); this is the keypad's identification number from

 

 

 

the central station operator's point of view. 01Ð06 is recommended.

 

 

¥

Keypad's partition (1Ð2).

 

 

¥

Keypad's sounder option (0Ð2)

Program VIM fault and siren silencing options by using the #93 Menu Mode - Relay Programming menu (see Section 4 in the PART 2. PROGRAMMING GUIDE section of this manual).

AAV

Notes

1.

The 685 Receiver software must be rev. 4.6 or higher. Earlier versions will not

 

 

 

hold the phone line connection, or if AUTO CALLBACK is enabled, any

 

 

 

receiver can be used.

 

 

2.

Contact ID code for "listen-in to follow" is "606" if AUTO CALLBACK is

 

 

 

disabled.

 

 

3.

Field 1*60 must be set for "0" when using the Ademco VIM module. If using

 

 

 

another manufacturerÕs AAV module, enter Ò1Ó.

 

 

 

NOTE: If set to Ò1Ó, zone 5 is no longer available as a

 

 

 

protection zone.

 

 

4.

Contact ID (field *45 =1) is the only reporting format that will send a "listen-in

 

 

 

to follow" message if AUTO CALLBACK is disabled.

 

 

5.

Listen-in to follow message is sent only if both the VIM and at least one

 

 

 

6139AV 2-way voice keypad is programmed using #93 Device Programming

 

 

 

mode if AUTO CALLBACK is disabled.

 

 

6.

Operator callback and AUTO CALLBACK option is enabled if a non- leading-

 

 

 

zero 4-digit number is programmed in field 1*59.

 

 

7.

Make sure that field *44 (RING DETECTION COUNT) is not set to Ò01Ó.

6139AV Keypad

Audio

The 6139AVÕs audio level for "talk mode" and "VOX mode" can be programmed

Level Adjustment

for "high," "medium," or "low." The factory default is "high."

 

 

1.

Enter the keypad's programming mode by pressing and holding down the [1]

 

 

 

and [3] keys at the same time for 3 seconds. The keypad's address is

 

 

 

displayed.

 

 

2.

a. Press and hold down the "D" key for 2 seconds. The current talk mode

 

 

 

audio level is displayed (high, medium, or low).

 

 

 

b. Press the [#] key repeatedly to toggle the talk mode level settings from

 

 

 

high to medium to low until the desired level is displayed.

 

 

3.

a. Press the "D" key again to enter VOX mode level setting. The current

 

 

 

VOX mode audio level is displayed (high, medium, or low).

 

 

 

b. Press the [#] key repeatedly to toggle the VOX mode level settings from

 

 

 

high to medium to low until the desired level is displayed.

 

 

4.

Pressing the "D" key again returns to the talk mode level setting, etc.

 

 

 

Press [*] to exit keypad programming mode.

Notes:

¥The keypad returns to normal mode if no key is pressed for 30 seconds.

¥Powering down the keypad does not change the level setting.

¥To eliminate undesired keypad feedback (microphonics) during a 2-way audio session, reduce the VOX mode audio level one level at a time until the feedback stops.

Ð37 Ð