Device Programming

This menu is used to program keypads, receivers and relay modules.

From Data Field Programming mode, press #93 to display "ZONE PROG?". Press 0 repeatedly to display "DEVICE PROG?".

DEVICE PROG?

Press 1 to enter DEVICE PROGRAMMING mode.

1=YES 0=NO

 

 

 

DEVICE ADDRESS 01-15, 00 = QUIT

DEVICE TYPE

RF EXPANDER

HOUSE ID XX

MODULE PARTITION?

VOICE KEYPAD NO. 01-15

CONSOLE PART.

SOUND OPTION

Enter the 2-digit device number as set by the device's DIP switches (01-15). Press [*] to accept entry. Enter 00 to return to the main menu. See NOTE below.

Select the type of addressable device as follows: 00 = device not used

01 = alpha keypad (6139)

02 = fixed word keypad (6128, 6137)

03 = RF receiver (4281/5881)

04 = output device (4204 relay module)

05 = phone module (4285)

07 = VIM voice interface module (refer to VIM

Êmenu prompts on the following page if this

Êdevice type is selected)

08 = 6139AV 2-way voice/alpha keypads Press [*] to accept entry.

If device type 03 (RF receiver) is selected, this prompt will appear. Enter the 2-digit house ID (00-31)

If device type 05 (phone module) is selected, this prompt will appear. Enter the partition number 1-2 in which the phone module is located.

If device type 08 (2-way voice keypad) is selected, enter the voice keypadÕs number. The voice keypads should be numbered in order, starting from

01.For example, if it is the first voice keypad, enter 01; if it is the second, enter 02, etc. This number is used by the central station operator to locate and communicate with the premises in case of an emergency. 01-06 is recommended. Press [*] to accept entry.

If device type 01, 02 or 08 was selected this prompt will appear. Enter the addressable device's default partition number (01 to maximum number of partitions programmed for system in field 2*00). This is the primary partition for which the device is intended to be used. Press [*] to accept entry.

If device type 01, 02 or 08 was selected this prompt will appear. Addressable keypads can be individually programmed to suppress arm/disarm beeps, entry/exit beeps and chime mode beeps. This helps prevent unwanted sounds from disturbing users in other areas of the premises.

Enter a number 00-03 for the keypad sounding suppression options desired for the keypad as follows:

00 = no suppression.

01 = suppress arm/disarm & entry/exit beeps.

02 = suppress chime mode beeps only.

03 = suppress arm/disarm, entry/exit and chime

ÊÊÊÊmode beeps.

The screen will display the next device number to be programmed. Press 00 to exit Menu Mode.

Ð 63 Ð

NOTE: Keypad address 00 will always be set to an alpha keypad with no sounder suppression options.