| Type 05 | This zone type will give an instant alarm if faulted when armed in the Away, Stay, |
Trouble | by Day/Alarm | Instant or Maximum (night) modes. During the disarmed state (day), the system |
| by Night. | will provide a latched trouble sounding from the keypad (and a central station |
|
| report, if desired). This zone type is usually assigned to a zone which contains a |
|
| |
|
| "sensitive" area such as a stock room, drug supply room, etc. This zone type can |
|
| also be used on a sensor or contact in an area where immediate notification of an |
|
| entry is desired. |
| Type 06 | This zone type sends a report to the Central Station but provides no keypad |
| Silent Alarm. | display or sounding. This zone type is usually assigned to a zone containing an |
|
| Emergency button. |
| Type 07 | This zone type sends a report to the Central Station, and provides an alarm sound |
| at the keypad, and an audible external alarm. This zone type is usually assigned to | |
|
| a zone that has an Emergency button. |
| Type 08 | This zone type sends a report to Central Station and provides an alarm sound at |
the keypad. (No bell output is provided). This zone type is usually | ||
| Alarm. | assigned to a zone containing a button for use in personal emergencies, or to a |
|
| zone containing monitoring devices such as water sensors, temperature sensors, |
|
| etc. |
| Type 09 | This zone type provides a fire alarm on short circuit and a trouble condition on |
Supervised Fire. (No | open circuit. The bell output will pulse when this zone type is faulted. This zone | |
| Verification) | type is always active and cannot be bypassed. This zone type can be |
|
| assigned to any |
|
| zone, and certain wireless zones. |
| Type 1 0 | This zone type gives entry delay (using the programmed entry delay 1 time), if |
Interior w/Delay. | tripped when the panel is armed in the Away mode. This zone type is also active | |
|
| during maximum mode, but no delay is provided (alarms occur immediately if zone |
|
| is tripped). This zone type is bypassed when the panel is armed in |
|
| the Stay or Instant modes. Delay begins whenever sensors in this zone are |
|
| violated, regardless of whether or not an entry/exit delay zone was tripped first. |
| Type 20 | This is a |
| units which will result in arming the system in the STAY mode when the zone is | |
|
| activated. |
| Type 21 | This is a |
| units which will result in arming the system in the AWAY mode when the zone is | |
|
| activated. |
| Type 22 | This is a special purpose zone type used with 5800 series wireless pushbutton or |
| Disarm* | contact closure or opening, and which will result in disarming the system when |
|
| the zone is activated. |
| Type 23 | This zone type can be used on a zone when an output relay action is desired, but |
No Alarm Response | with no accompanying alarm (ex. lobby door access). | |
|
| * These zone types are not for use by 5700 series devices. |
|
|
|
|
| NOTE FOR PANIC KEYS |
|
| Keypad panic zones share the same zone response type for both partitions, but |
|
| panics may be individually enabled for each partition. |
|
|
|
|
|
|
|
| IMPORTANT! FAULT ANNUNCIATION |
|
| Phone module, RF, VIM and polling loop faults (zones 87, |
|
| report as trouble conditions only, and as such, should be assigned either zone |
|
| type 00 if no annunciation is desired, or zone type 05 if annunciation as trouble |
|
| condition is desired. See FAULT ANNUNCIATION notes in POLLING LOOP and |
|
| WIRELESS EXPANSION sections for more information. |
|
|
|