Type 05

This zone type will give an instant alarm if faulted when armed in the Away, Stay,

Trouble

by Day/Alarm

Instant or Maximum (night) modes. During the disarmed state (day), the system

 

by Night.

will provide a latched trouble sounding from the keypad (and a central station

 

 

report, if desired). This zone type is usually assigned to a zone which contains a

 

 

foil-protected door or window (such as in a store), or to a zone covering a

 

 

"sensitive" area such as a stock room, drug supply room, etc. This zone type can

 

 

also be used on a sensor or contact in an area where immediate notification of an

 

 

entry is desired.

 

Type 06

This zone type sends a report to the Central Station but provides no keypad

24-hour

Silent Alarm.

display or sounding. This zone type is usually assigned to a zone containing an

 

 

Emergency button.

 

Type 07

This zone type sends a report to the Central Station, and provides an alarm sound

24-hour Audible Alarm.

at the keypad, and an audible external alarm. This zone type is usually assigned to

 

 

a zone that has an Emergency button.

 

Type 08

This zone type sends a report to Central Station and provides an alarm sound at

24-hour Auxiliary

the keypad. (No bell output is provided). This zone type is usually

 

Alarm.

assigned to a zone containing a button for use in personal emergencies, or to a

 

 

zone containing monitoring devices such as water sensors, temperature sensors,

 

 

etc.

 

Type 09

This zone type provides a fire alarm on short circuit and a trouble condition on

Supervised Fire. (No

open circuit. The bell output will pulse when this zone type is faulted. This zone

 

Verification)

type is always active and cannot be bypassed. This zone type can be

 

 

assigned to any hard-wired zone except zone 9, any polling loop

 

 

zone, and certain wireless zones.

 

Type 1 0

This zone type gives entry delay (using the programmed entry delay 1 time), if

Interior w/Delay.

tripped when the panel is armed in the Away mode. This zone type is also active

 

 

during maximum mode, but no delay is provided (alarms occur immediately if zone

 

 

is tripped). This zone type is bypassed when the panel is armed in

 

 

the Stay or Instant modes. Delay begins whenever sensors in this zone are

 

 

violated, regardless of whether or not an entry/exit delay zone was tripped first.

 

Type 20

This is a special-purpose zone type used with 5800 series wireless pushbutton

 

Arm-Stay*

units which will result in arming the system in the STAY mode when the zone is

 

 

activated.

 

Type 21

This is a special-purpose zone type used with 5800 series wireless pushbutton

 

Arm-Away*

units which will result in arming the system in the AWAY mode when the zone is

 

 

activated.

 

Type 22

This is a special purpose zone type used with 5800 series wireless pushbutton or

 

Disarm*

contact closure or opening, and which will result in disarming the system when

 

 

the zone is activated.

 

Type 23

This zone type can be used on a zone when an output relay action is desired, but

No Alarm Response

with no accompanying alarm (ex. lobby door access).

 

 

* These zone types are not for use by 5700 series devices.

 

 

 

 

 

NOTE FOR PANIC KEYS

 

 

Keypad panic zones share the same zone response type for both partitions, but

 

 

panics may be individually enabled for each partition.

 

 

 

 

 

 

 

 

IMPORTANT! FAULT ANNUNCIATION

 

 

Phone module, RF, VIM and polling loop faults (zones 87, 88-91, 93 & 97) will

 

 

report as trouble conditions only, and as such, should be assigned either zone

 

 

type 00 if no annunciation is desired, or zone type 05 if annunciation as trouble

 

 

condition is desired. See FAULT ANNUNCIATION notes in POLLING LOOP and

 

 

WIRELESS EXPANSION sections for more information.

 

 

 