Section 1.

GENERAL PROGRAMMING PROCEDURES

GENERAL INFORMATION

Review the global and specific partitioning features listed in the GENERAL INFORMATION section of the Installation Instructions before programming the system.

User-Friendly Zone, Device

& Alpha

Programming

(#93 Menu Mode)

Communication Default Programming

Entering The Various Program Modes

The system is shipped with a set of pre-programmed default values that are designed to meet the needs of many installations. These can be changed by the installer to suit specific needs if desired, by using a 6139 (AV) alpha keypad*. In addition, four sets of pre-programmed communication default values can also be loaded by the installer, each set designed for a specific communication format. These too can be changed to suit the needs of a particular installation.

Changes to these pre-programmed values can be programmed directly from the alpha keypad or from an IBM compatible computer either remotely (using an approved modem) or at the job site (direct wire downloading using the 4100SM

Serial Module). Both methods use the AdemcoÕs V-Link¨downloading software (Rev. 4 or higher) or AdemcoÕs Compass Windows downloading software (be sure that the software version used includes a VISTA-40 selection).

For alpha keypads, English Language descriptions of the zones and a custom installer message (which appears when the system is ready to arm) can be programmed using the built-in vocabulary of words (see #93 MENU MODE, ALPHA PROGRAMMING section).

*NOTE: The factory loaded defaults (*97) enable keypad addresses 00-03 only. ÊA keypad with one of these addresses must be used to program the system. If Ênecessary refer to ÒSetting the Keypad AddressÓ in Section 4.

To help set up a partitioned environment quickly and accurately, a user friendly menu mode has been added. Instead of the traditional method of programming all the fields associated with zones and the partitions they are associated with, you may now logically program a zone for all its characteristics as prompted by the keypad (refer to the #93 MENU MODE section for details). This ensures that you assign each zone to a partition and that a zone response type has been assigned.

This User Friendly Menu Mode steps you through the programming options by prompting you to answer simple yes/no questions. In addition to zone programming, this mode is also used for programming remote keypad characteristics, for entering alpha descriptors for wireless & polling loop module serial number "enrolling" and for relay programming.

There are four sets of pre-programmed communication defaults available, including Low Speed, 4+2 Express, Ademco High Speed, and Ademco Contact ID. Loading one of these defaults automatically programs industry standard report codes that will suit most of your needs. These codes can also be changed as required. Refer to the COMMUNICATION PROGRAMMING section for instructions.

Data Field Programming mode can be entered in one of two ways.

A)By depressing the [*] and [#] keys at the same time within 30 seconds after power is applied to the Control. This method can be suppressed in program field 1*65.

B)By keying the installer code, followed by depression of [8]+ [0]+ [0] keys. The factory installer code can be changed once in the program mode. This method can be suppressed by exiting program mode via *98.

After entry into the program mode, the following will be displayed on an alpha keypad:

Program Mode

*Fill # View - 00

Following this display, the system is ready to be programmed.

#93 Menu Mode is entered by pressing #93 while in data field programming mode.

Ð 41 Ð

Page 41
Image 41
Guardian Technologies VISTA-40, N7001V2 installation instructions General Information, 41 Ð