DATA FIELD DESCRIPTIONS

The following section arranges the global (system wide) program fields into the following functional groups:

Control Options Downloading Options Dialer Options Wireless Options Partitioning Options Event Logging Options

 

 

 

 

Note that zone response types can be programmed in fields *02-*05 &

 

 

 

 

1*01-1*09, but it is recommended that they be programmed via the #93 Menu

 

 

 

 

Mode. For this reason, these fields are not discussed in this section.

Control Options

 

 

* 0 0

Installer Code

The Installer's Code is a 4-digit code reserved for installation company use, but

 

 

 

 

can be used by the customer if needed. This is the only code that can be used to

 

 

 

 

enter the Program mode from the keypad. This code cannot be used to disarm

 

 

 

 

the system if not used to arm, or if Quick Arm was used to arm system. This code

 

 

 

 

cannot reenter programming mode if exited by the *98 command.

* 1 4

Zone 9

 

 

Enter 1 to set fast response mode (10 mSec) for appropriate devices wired to

 

Response Time

zone 9. Enter 0 for normal response, 350 msec. Must be 0 for UL.

* 1 5

Keyswitch

Enter the partition number 1-2in which the keyswitch is being used; otherwise,

 

Assignment

enter 0. Requires the use of zone 7 wired loop (zone 7 no longer available as

 

 

 

 

protection zone when used for keyswitch operation). If the keyswitch is used, the

 

 

 

 

fire and panic alarm voltage triggers automatically become ARMING and READY

 

 

 

 

status outputs for support of the Keyswitch LEDs. NOTE: Zone type 10 is

 

 

 

 

automatically assigned to zone 7 if a keyswitch is used. Reports openings/closing

 

 

 

 

by user "0" if reporting is enabled in field *40.

* 1 7

AC Loss Keypad

Entering 1 enables sounding at the keypad (rapid beeping) when AC power is

 

Sounding

lost is desired. Enter 0 if no AC power loss keypad sounding is desired.

* 1 8

UL AC Loss

Entering 1 enables the external alarm sound after AC power has been out for 4

 

Siren

 

 

hours; otherwise enter 0 (no alarm).

* 1 9

Randomize

Enter 1 to randomize AC loss reporting between 10-40 min. after an actual AC

 

AC Loss Report

loss. Enter 0 for normal AC loss reporting (about 2 minutes after actual AC loss).

 

 

 

 

Selecting this option helps prevent an overload of AC loss messages at the central

 

 

 

 

station during a community blackout.

* 2 0

Phone

Module

If an 4285 phone module is being used, enter the 2-digit phone code used to

 

Phone

Code

access the system. Enter 01-09 for first digit, and enter 11 (for T) or 12 (for #) for

 

 

 

 

second digit. To disable the phone module, enter 00 for the 1st digit and enter

 

 

 

 

11 for the 2nd digit of the code (disable code = [0T]). Must be disabled for UL

 

 

 

 

installations.

* 2 1

Prevent

Fire

Enter 1 to disable (no timeout) the alarm sounder duration for any zone

 

Time-Out

designated as a fire zone, regardless of partition, so that fire sounding continues

 

 

 

 

until the system is reset. Enter 0 if the normal burglary alarm sounder duration

 

 

 

 

(programmed in partition-specific field *13) should apply to fire alarms.

* 2 4

Ignore

Expansion

Only applicable if certain polling loop RPMs or 5800 series transmitters are used.

 

Zone Tamper

This option is used to disable this module's tamper detection. Enter 1 to disable.

 

 

 

 

Enter 0 if tamper detection is desired.

* 2 5

Burg. Trigger For

This field allows optional triggering of the voltage output on pin 7 of the J7 header

 

Response Type 8

for zone response type 8 (24hr. auxiliary). The 0 disable selection is useful if J7

 

 

 

 

header pin 7 is used for a panic trigger, and non-panic devices are used for all

 

 

 

 

zones assigned to zone response type 8 (e.g. water sensor, temp. sensor). If

 

 

 

 

disabled, only burglary or audible panic alarms will trigger pin 7. Otherwise, enter 1.

* 2 6

Intelligent

Enter 1 if it is desired that no test report be sent if any other type of report was sent

 

Test Reporting

since the last test report. Enter 0 if test reports are to be sent at the set intervals,

 

 

 

 

regardless of other reports having been sent. Must be 0 for UL applications.

Ð 47 Ð