E NTE R ZN NO .

0 0 = Q UIT

1 0

Zone 10 entered

1 0 ZT P RC IN: L

0 0 – – – – – :

Zone Number

1 0 ZO NE TYP E

P e rime t e r

0 3

Entry for Zone Type 03

shown

1 0 P A RTITIO N

2

1 0 RE P O RT CO DE 1 st 0 3 2 n d 1 2 3 C

10 INPUT TYPE

 

RF Xmitter

3

4.Enter the zone number that you wish to program. As an example, zone 10 is shown here. Press [] to continue.

5.A display will appear, showing a summary of that zone's programming. If the zone is not programmed, the display will appear as shown here. If checking a zone's programming, and it is programmed satisfactorily, press

[#]to back up one step and enter another zone number, if desired. Otherwise, press [] to continue.

6.Each zone must be assigned a zone type, which defines the way in which the system responds to faults in that zone. Enter the zone type desired (or change it, if necessary). Available zone types are listed below.

00 = Assign For Unused Zones

08 = 24 Hr Aux

01 = Entry/Exit #1, Burglary

09 = Fire

02 = Entry/Exit #2, Burglary

10

= Interior Delay, Burglary

03

= Perimeter, Burglary

20

= Arm–Stay*

04

= Interior Follower, Burglary

21

= Arm Away*

05 = Trouble Day/Alarm Night

22

= Disarm*

06 = 24 Hr Silent

23

= No Alarm Response

 

(EX: Relay activation)

07 = 24 Hr Audible

 

 

 

*These are special zone of types used with 5800 series wireless push-button units which will result in arming the system in the STAY or AWAY mode, or disarming of the system, depending on the selection made.

Press [] to continue.

7.Enter the partition number you are assigning this zone to.

Press [] to continue.

8.Enter the report code. The report code consists of 2 hexadecimal digits, each in turn consisting of 2 numerical digits. For example, for a report code of "3C", enter [0][3] for "3" and [1][2] for "C."

(Refer to System Communication section in the applicable Installation Instructions for more information about report codes and report code formats.)

Press [] to continue.

9.Enter the RF transmitter or serial number polling loop input device type as follows:

3 = RF (supervised RF transmitter)

4 = UR (unsupervised RF transmitter)

5 = BR (button type RF transmitter - unsupervised)

6 = SL (serial polling device)

(Refer to the Installation Instructions for more information about input types.)

Press [] to continue.

Ð 2 Ð