NOTE: 4204 Relay Module must be rev. "V3" or higher to activate temporal pulsing.

02 ÊÊA EV ZL ZT P STT Ê 0Ê 0 0 00

02 ÊÊA EV ZL ZT P STOP 0 0 0 00

02RELAY ACTION NO RESPONSE

02START EVENT NOT USED

02 START: ZN LIST NO LIST

02 START: ZN TYPE

02 START PART

02 STOP: ZN LIST NO LIST

02 STOP: ZN TYPE

02 STOP PART

RESTRICTION 1=YES 0=NO

RELAY TYPE

HOUSE CODE

UNIT CODE

ECP ADDRESS

MODULE RELAY #

The keypad will display a summary START screen.

The keypad displays a summary STOP screen.

Enter the desired relay action as follows:

0=not used; 1=closed for 2 secs.; 2=stay closed; 3=pulse on/off (temporal pulse).

Note: The 4204 relay must have ÒV3Ó later installed to activate temporal pulse.

Enter the event code to start the relay action as follows: 0=not used; 1=alarm; 2=fault; 3=trouble; 4=restore

If a zone list is being used to start this relay action, enter the zone list number 1-4. If a zone list is not being used, enter 0.

If a zone type/system operation is being used to start the relay action, enter the 2-digit Zone Type/System Operation number from the list shown earlier in the RELAY PROGRAMMING section.

Enter 0 for any partition. Enter 1-2for specific partition number.

If a zone list is being used to stop this relay action, enter the zone list number 1-4. If a zone list is not being used, enter 0.

If a zone type/system operation is being used to stop the relay action, enter the 2-digit Zone Type/System Operation number from the list shown earlier in the RELAY PROGRAMMING section.

Enter 0 for any partition. Enter 1-2for specific partition number.

The system may have some devices which are not intended to be under end user control, such as relays activating fire doors or machinery. Enter 1 if the end user will be restricted from accessing this relay group.

Enter 1 for relays. Enter 2 for X-10 devices.

For X-10 devices, enter the letter house code. A=0, B=1, C=2, etc. (00-15)

For X-10 devices, enter the numerical unit code (01-15)

For relay module (4204) outputs, enter the actual relay module's address set by its DIP switch (01-15). Up to 2 modules can be installed in a system.

For relay module (4204) outputs, enter the specific relay number on that module (1-4).

The keypad displays the two summary screens again.