Guardian Technologies VISTA-40 Data Field Programming, Programming SYSTEM-WIDE Global Data Fields

Models: N7001V2 VISTA-40

1 122
Download 122 pages 53.89 Kb
Page 45
Image 45

Section 3. DATA FIELD PROGRAMMING

PROGRAMMING SYSTEM-WIDE (GLOBAL) DATA FIELDS

General Procedure

The global (i.e. non partition-specific) programming fields are grouped into three

 

sets (referred to as "pages"), as represented in the diagram below. The first page

 

of fields is accessed automatically after entering a field number. To access the

 

other pages of fields (indicated on the programming form by a "1" or "2" in front of

 

the 2-digit field address), press *94. Note that the alpha keypads display the

 

words ALT PROGRAM MODE along with a "1" or "2", depending on which page

 

of programming fields are accessed, to indicate the higher page of fields. To

 

return to the previous page of fields, press *99.

 

Enter programming mode

 

(installer code + [8] + [0] + [0])

 

Enter the first field number (ex. *00, installer's code)

 

to move to first page

First Page of fields (*00-*90)

press *99 or *98 to exit program mode

press

*94

to move to 2nd page

press *99

to move back to 1st page

 

 

 

second page of fields

 

 

 

 

 

 

(1*01-1*76)

 

 

press

*94

to move to 3rd page

press *99

to move back to 2nd page

third page of fields (2*00-2*21)

To program specific data fields, press [*] plus the 2-digit field address, then make the required entry. The keypad will beep when a field has been completely programmed and will automatically display the next field in sequence. Partitioned programming fields are skipped (refer to PARTITIONING PROGRAMMING paragraph). If the number of digits that you enter in the data field is less than the maximum permitted (ex. phone number), the keypad displays the last entry and waits. To proceed, the next data field to be programmed must be entered manually (ex. press [*][0][5]).

To view the contents of a data field, press [#] plus the 2-digit field address. The field's entries will be displayed, but no changes can be made.

In case of errors: If an address is improperly entered, the keypad will display FC. If a program entry is improperly entered (for example, a larger number than that which is permitted), the keypad display will go blank. In either case, simply re- enter the correct number.

SUMMARY OF DATA FIELD PROGRAMMING COMMANDS

*9 4 Next page of fields

*9 9 Previous page of fields or exit programming mode with no installer lockout

*9 1 Select partition for programming partition-specific fields

# 9 3

Enter Zone/Alpha/Device Programming mode

* 9 8

Exit programming mode with installer code lock-out

Ð 45 Ð

Page 45
Image 45
Guardian Technologies VISTA-40, N7001V2 Data Field Programming, Programming SYSTEM-WIDE Global Data Fields