Zone List Programming After entering all relay menu items, up to four (4) zone lists can be entered by entering 00 at the ENTERÊRELAYÊNo. prompt.

Enter Zone LIST 00=QUIT 00

Enter the zone list number 1-4.

01Enter Zn Num. 00=QUIT 00

01 Del Zn LIST?

01 Delete Zone? 0=NO 1=YES

01Zn to Delete? 00=QUIT 00

View Zn LIST 00=QUIT 00

Enter each zone to be included in this zone list, pressing [*] to enter each zone number.

Enter 0 to save the zone list entered. Enter 1 to delete that zone list.

Enter 1 to delete one or more zones in that zone list. Enter 0 if no changes are necessary. If 1 is entered, the following screen will appear, otherwise the zone list no. prompt will reappear.

Enter each zone number to be deleted from the zone list, pressing [*] after each number.

This will appear if 00 is pressed at the ENTER ZONE LIST prompt. Enter the zone list number that you wish to view.

XXASSIGNED ZONE 00=QUIT 00

Press [*] to scroll through all zones in that list. Enter 00 to quit.

Programming Relays for

The system can be programmed to silence external sounders during a 2-way

Silencing of External

voice session (VIM active) by using two relays connected in series. An example

Sounders When Using the

shows relays 1 and 2 of the Relay Module connected as shown in the diagram

VIM

below. Program the relay that controls the bell/siren (#1) as usual and the other

 

relay (#2) as shown below. This programming enables the sounders when the

 

VIM is not active and disables the sounders when the VIM is active.

 

Ex. Relay #2 programming:

02 RELAY ACTION

 

STAY CLOSED

2

Enter the relay action as 2 (stay closed).

02START EVENT

ALARM 1

Enter start and stop events as 1 (alarm).

02 START: ZN LIST

 

NOT USED

0

Enter 0 (not used) for start and stop zone list.

02 START: ZN TYPE

VIM ACTIVE

65

Enter start zone type 65 (VIM Active).

02 STOP: ZN TYPE

 

VIM INACTIVE

66

4204 RELAY MODULE

Enter stop zone type 66 (VIM Inactive).

TO

+

6

5RELAY # 2

4

BELL

3

 

2RELAY # 1

1TO Ð

TO CONTROL'S

KEYPAD TERMINALS SIREN

Ð 68 Ð

Page 68
Image 68
Guardian Technologies N7001V2, VISTA-40 installation instructions Ex. Relay #2 programming, 68 Ð