Remote Keypad Sounder

An optional Amseco PAL 328N can be used for installations where it is desired to

Operation & Wiring

remote the sounds produced by the keypad's built-in piezo sounder for one

 

partition. The panel will remote all sounds (i.e. alarm, trouble, chime, entry/exit,

 

etc.) produced by the keypad's built-in sounder except for the short clicks

 

associated with keypad key depression. One application of this feature might be

 

to produce chime sounds in a location which is distant from the panel's keypads.

 

This can also be accomplished using relay outputs (see Output Relay section).

 

If used, program field 1*46 must be set to "2" to enable the remote keypad

 

sounder option, and the Amseco piezo must be connected between the panel's

 

auxiliary power and the J7 connector trigger output as shown below.

 

In addition, field *15 must be used to select the partition whose keypad sounds

 

are to trigger the sounder. Zone 7 must be assigned to be a keyswitch zone

 

(even if keyswitch is not used).

IF USED.

4142TR CABLE

J7 CONNECTOR

1.OUT 1 IS NO LONGER USABLE FOR OPEN/CLOSE OR GROUND START (SEE FIELD 1*46).

2.OUT 2, 3, 4 CAN STILL BE USED TO PROVIDE ALARM STATUS INDICATIONS OR TO OPERATE A KEYSWITCH (SEE FIELD *15).

TO AUX POWER +

TERMINAL 6RED (10mA CURRENT DRAW)

BLACK

AMSECO PAL-328N

PIEZO SOUNDER

+

GROUND OUT 1

GROUND OUT 2

GROUND OUT 3

GROUND OUT 4

GRAY

YELLOW

WHITE

RED

GREEN

BROWN

BLUE

BLACK

N/U

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

REMOTE KEYPAD SOUNDING CONNECTIONS

Using A Trigger To If using an Audio Alarm Verification module from another manufacturer, and a Activate Another voltage trigger will be used to activate the module, make connections as shown ManufacturerÕs AAV below. In addition, set program field 1*46 to option 3, and program zone 5 for

Unit (if necessary) response type 10; also, program field 1*60 for Ò1Ó.

Note: If field 1*60 is set for Ò1Ó, zone 5 cannot be used as a protection zone, and the EOLR must be removed. Refer to the 2-WAY VOICE KEYPADS & AUDIO ALARM VERIFICATION section later in this manual for additional information.

4142TR CABLE

J7 CONNECTOR

TO AUDIO ALARM

VERIFICATION MODULE

(AAV) FALLING EDGE

 

 

TRIGGER INPUT

 

 

ON THE AAV UNIT

DIODE INCLUDED

 

WITH EOLR

 

PACKAGE

GROUND OUT 1

GROUND OUT 2

GROUND OUT 3

GROUND OUT 4

GRAY

YELLOW

WHITE

RED

GREEN

BROWN

BLUE

BLACK

N/U

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

USING A TRIGGER TO ACTIVATE A NON-ADEMCO AAV UNIT

Ð 30 Ð

Page 30
Image 30
Guardian Technologies N7001V2 Remote Keypad Sounding Connections, Using a Trigger to Activate a NON-ADEMCO AAV Unit, 30 Ð