Zone Programming

Important!: Note that before programming zone characteristics, field 2*00 (number of partitions) and field 1*32 (receiver type) must be programmed. This identifies the use of RF Receivers and the number of partitions being used in the system.

Enter Programming mode, then press #93 to display "ZONE PROG?".

ZONE PROG? 1=YES 0=NO

ENTER ZN NO. 00=QUIT 20

Press 1 to enter ZONE PROGRAMMING mode. The following screens will appear. Press [*] to display the next screen. Press # to display a previous screen.

Enter the zone number to be programmed (01-64, 87-91, 92, 93, 95, 96, 97 or 99). Press [*] to accept entry. Enter 00 to return to the main menu selections.

Summary Screen -

Zn ZT P RC In:Ê L 20 00 1 00 RF:ÊN

20ZONE TYPE ZONE DISABLED 00

20 PARTITION

20 REPORT CODE

A summary screen for that zone will appear. The "N" after the colon indicates the loop number to which the sensor is connected.

Each zone in a system must be assigned to a zone type, which defines the way in which the system responds to faults in that zone. Refer to the ZONE TYPE DEFINITIONS section for definitions of each zone type. Enter the zone response type for each zone. The screen will automatically display the zone type for the number entered. Press [*] to accept entry. If a different zone response type is desired, enter a different number and press [*].

For UL applications, use of 1 or 2 RF receivers requires enabling their respective faults (88-91) as applicable (type 5).

Zone Types are as follows:

00Assign for unused zones

01Entry/Exit #1, burglary

02Entry/exit #2,

03Perimeter, burglary

04Interior follower, burglary

05Trouble by day/Alarm by night, burglary

0624 hour silent alarm

0724 hour audible alarm

0824 hour auxiliary

09Fire

10Interior delay, burglary

20Arm-stay (for 5800 transmitters only)

21Arm-away (for 5800 transmitters only)

22Disarm (for 5800 transmitters only)

23No alarm response

Enter the partition number (1-2) in which this zone is located.

Enter the report code for this zone.

Ð 56 Ð

Page 56
Image 56
Guardian Technologies N7001V2 Zone PROG? 1=YES 0=NO Enter ZN no =QUIT, Zone Type Zone Disabled Partition Report Code, 56 Ð