VIM Voice Interface Module Prompts

If device type 7 (VIM) is selected, the following prompts will appear.

NOTE: The VIM reports supervisory faults as zone 93. Make sure to program a response type (trouble = response type 05) and report code to zone 93 using #93 Menu Mode - ZONE PROGRAMMING.

VIM PARTITION?

MAX 2WAY T.O.

Enter the partition number as follows:

0 = Automatic Mode, which means that 2-way voice activates only in the partition in which the alarm occurred. (maximum of six 6139AV keypads per system)

1 = Partition 1 Only, which means 2-way voice activates in partition 1 only and only upon alarms occurring in partition 1. (maximum of six 6139AV keypads per partition)

2 = Partition 2 Only, which means 2-way voice activates in partition 2 only and only upon alarms occurring in partition 2. (maximum of six 6139AV keypads per partition)

3 = All Mode, which means 2-way voice activates in all partitions upon alarms in any partition. In this mode, a maximum of six 6139AV keypads can be used in the system and there can be no duplicate Voice keypad numbers between the partitions.

Press [*] to accept entry.

At the end of this timeout, the system automatically ends a 2-way voice session. Enter the maximum 2- way voice session timeout as follows:

0 = 5 minutes (default)

1 = 10 minutes

2 = 15 minutes (typical)

3 = no timeout (used when testing the system) Press [*] to accept entry.

Ð 64 Ð

CHIME OTHERS

VIM TEXT?

VIM AC LOSS

AUTO CALL BACK

This prompt allows chime and alarm sounds to be turned on or off in partitions other than the one in which a 2-way voice session is active as follows:

0 = Off, do not sound chimes or alarms in other partitions during a 2-way voice session

1 = On, do allow chimes and alarm sounds to occur in other partitions during a 2-way voice session, except if VIM Partition is set to "3" ALL mode.

Press [*] to accept entry.

If enabled, this option displays the VIM mode status at the keypad (e.g., LISTEN MODE), which can be helpful when testing the system. Enter 1 to select. Enter 0 if not desired. Press [*] to accept entry. NOTE: Panic zones (95, 96 and 99) will not display 2-way voice mode messages regardless of whether VIM TEXT is enabled.

This option, if selected, allows the VIM to Òlisten-inÓ in the event of the system's AC loss (it then operates using the backup battery power). This is recom- mended for installations where life support devices are used, such as a dialysis machine. Enter 1 to select. Enter 0 if operation upon power failure is not desired. Press [*] to accept entry.

If enabled, this option allows the Central Station to call back and initiate 2-way voice communication within 5 minutes after an alarm report is sent. Otherwise, a ÒListen in to FollowÓ message (Contact ID event code Ò606Ó) is sent at the end of the report to initiate 2-way voice communication immediately.

Page 64
Image 64