Using A Non-Ademco Audio

If you prefer to use another manufacturerÕs AAV unit in place of the Ademco VIM

Alarm Verification (AAV) Unit

unit, contact the manufacturer for information regarding the wiring of their unit to

 

the VISTA-40. When using another manufacturerÕs AAV unit, see Notes below.

 

Some AAV modules allow remote triggering by ring detection at the alarm

 

installation. Please be advised that if this option is selected, it may defeat modem

 

download and 4285 phone module remote access capability. To prevent this,

 

disable the remote AAV module trigger option. The control also requires that the

 

AAV module trigger type is falling edge.

IMPORTANT NOTES:

¥685 Receiver software must be rev. 4.6 or higher. Earlier versions will not hold the phone line connection.

¥Field 1*60 must be set for "1."

Note: When this field is set to Ò1Ó, zone 5 can no longer be used as a protection zone.

The purpose of zone 5 is to silence the sounders on the control when an open circuit condition occurs, signalling the start of an AAV session. The open circuit must be triggered by the AAV module (i.e., a relay). Contact the AAV moduleÕs manufacturer for specific details.

¥Zone 5 must be assigned a response type 10.

¥Field 1*46 must be set for Ò3Ó if the AAV unit requires a trigger. See ÒUsing A Trigger To Activate Another ManufacturerÕs AAV UnitÓ in the VOLTAGE TRIGGER (Connector J7) in Section 5 previously.

¥If using a relay, such as the Ademco 4204, select Ò60Ó for System Operation, (see ÒRelay ProgrammingÓ in Section 4. PROGRAMMING WITH #93 MENU MODE).

¥Contact ID code for "listen-in to follow" is "606."

¥Contact ID (field *45 = 1) is the only reporting format that will send a "listen-in to follow" message.