Guardian Technologies VISTA-40, N7001V2 installation instructions Way Voice Test Mode, 101 Ð

Models: N7001V2 VISTA-40

1 122
Download 122 pages 53.89 Kb
Page 101
Image 101

2-Way Voice Test Mode

At the Protected Premises: To test the VIM and 6139AV keypad 2-way voice operation, both the installer at the protected premises and the central station operator do the following.

NOTE: The VIM has built-in LEDs which identify its operating mode. It can be helpful to view these LEDs when performing the following test. To view the LEDs, remove the VIM's cover and refer to the table that follows.

VIM STATUS LED FUNCTIONS

LED

STATE

MEANING

 

 

 

NO LED LIT

Off

VIM Idle

 

 

 

RED LIT

Steady

Talk to single keypad

 

 

 

 

Flashing

Talk to All Mode

 

 

 

GREEN LIT

Steady

VOX Mode

 

 

 

BOTH LIT

Steady

Listen to single keypad

 

Flashing in unison

Listen to All Mode

 

Alternating Flash

Waiting for operator's callback ID code

 

 

 

1.The installer enters the security code and presses #65 at a 6139AV 2-way voice keypad.

The keypad displays "AUDIO 2WAY TEST" momentarily and a test message is sent to the central station, with a "listen-in to follow" message (a Callback will be required if in the Auto Callback mode).

The keypad then initially displays the "LISTEN MODE" message (if so programmed via "VIM TEXT" option). Subsequently, this message changes, depending on the 2-way voice mode the central station operator selects (step 1 of "At the Central Station" below), such as "LISTEN MODE" (3 beeps), "TALK MODE" (1 beep), or "VOX MODE" (2 beeps).

2.The installer can say something verbally to the central station operator from this keypad to confirm that the "listen-in" is working properly.

3.The installer should speak out loud near each of the 2-way voice keypads so the operator can confirm their operation.

4.The installer can adjust the "Talk Mode" audio level using the procedure described earlier.

At the Central Station: 1. When the test message and listen-in to follow message is received, the operator lifts the receiver to begin a 2-way voice session and presses a command key (see VIM OPERATOR FUNCTIONS section earlier in this manual). If Auto Callback option is chosen, the operator will have to call back within 5 minutes to begin a 2-way voice session.

The system defaults to "LISTEN MODE."

2.The operator should listen for the installer's verbal message. The operator can then switch to "TALK MODE" or "VOX MODE" and say something to the installer at the premises to confirm proper operation of these modes.

3.The operator should switch to each of the other installed 2-way voice keypads and listen for the installer's verbal message.

4.The operator can switch to "talk Mode" and speak while the installer adjusts the keypad's audio level.

5.In partitioned systems, repeat this test in each partition.

To test the operator-initiated callback feature and audio ID number, the operator can enter Ò88Ó, hang up, and call back within 5 minutes and enter the proper ID code (field 1*59).

To end this test mode, the operator enters "99." This test mode also automatically ends after 90 seconds if no commands are issued.

Ð 101 Ð