Important!

Since the phone module, RF receiver(s), VIM and the polling loop are shared

Fault Annunciation

among the 2 partitions, the scheme for annunciating their failure follows:

 

Respective faults (for zones 87, 88Ð91, 93 & 97) will report as trouble conditions

 

only, and as such, should be assigned either zone type 00 if no annunciation is

 

desired, or zone type 05 if annunciation as trouble condition is desired. If the

 

polling loop or RF link fails supervision, the corresponding zone number will

 

display a trouble condition for each partition that uses the device that failed. In

 

addition, all zones associated with that device will indicate a check condition. The

 

trouble condition will not interfere with the ability to arm the partition, but the faults

 

must first be bypassed.

Compatible Polling Loop

4208

Eight Zone Polling Loop Expansion Module

Devices

 

Does not support 2-wire smoke detectors.

 

 

Set DIP switches to identify 8 zones.

 

 

 

 

4190WH

Two Zone Remote Point Module

 

 

The left zone can be EOLR supervised, if necessary, and can

 

 

accept either open or closed circuit sensors, and can be set for

 

 

fast response. The right zone is unsupervised and can accept

 

 

closed circuit sensors only.

 

4278

Quad Element Polling Loop PIR

 

 

DIP switch programmable and connects directly to the polling

 

 

loop. Features an auxiliary sensor loop that permits connection of

 

 

another nearby closed circuit alarm sensor (reed contact, etc.).

 

4275

Dual Element Polling Loop PIR

 

 

DIP switch programmable.

 

4194

Surface Mounted Reed Contact (Wide Gap)

 

 

DIP switch programmable.

 

4 1 9 7 / 4 2 9 7

Polling Loop Extender Module

 

 

By installing a 4297 at the end of the first loop, the polling loop

 

 

can be continued. If more than 64mA needs to be drawn from the

 

 

polling loop to power RPMs, use of the 4197/4297 provides

 

 

another loop with 64mA available. See instructions accompany-

 

 

ing unit.

 

 

 

 

4192SD

Photoelectric Smoke Detector

 

 

DIP switch programmable.

 

4192SDT

Photoelectric Smoke Detector w/Heat Detector

 

 

DIP switch programmable.

 

4192CP

Ionization Smoke Detector

 

 

DIP switch programmable.

 

4139SN

Auto Smart Surface Mount Reed Contact

 

 

Serial number ID "enrolled" by control panel.

 

 

Check product availability.

 

4191SN

Auto Smart Recessed Reed Contact

 

 

Serial number ID "enrolled" by control panel.

 

 

Check product availability.

 

4939SN

Auto Smart Surface Mount Contact

 

 

Serial number ID "enrolled" by control panel.

 

 

Check product availability.

 

4959SN

Auto Smart Overhead Door Contact

 

 

Serial number ID "enrolled" by control panel.

 

 

Check product availability.

 

998MX

Polling Loop PIR

 

 

Serial number ID "enrolled" by control panel.

Ð 21 Ð

Page 21
Image 21
Guardian Technologies VISTA-40 Eight Zone Polling Loop Expansion Module, 4190WH Two Zone Remote Point Module, 21 Ð