Manual Calibration
A manual calibration should be performed whenever you are using
1.Turn on the printer power.
2.Remove approximately 6” (152 mm) of labels from a section of backing material. Load the media so that only the backing material is threaded through the printer and under the printhead.
3.Use the Media Tracking (^MN) command to select the appropriate media type (refer to the ZPL II Programming Guide).
4.Press and hold the feed button until the green status LED flashes once, then twice. Release the feed button.
5.The printer will set the media sensor for the label backing being used. After it is done making this adjustment, the roll will automatically feed until a label is positioned at the printhead.
6.A profile of the media sensor settings (similar to the example in Figure 32) will print. Upon completion, the printer will save the new settings in memory and the printer is ready for normal operation.
7.Press the feed button. One entire blank label should feed. If this does not happen, try defaulting (refer to the
NOTE: Performing a manual calibration disables the auto calibration function. To return to auto calibration, default the printer (see the
Figure 32
34