Installation – External Blower Preparation

1.Place 10” round adapter on top of hood and secure with (4) M4x8 screws. Connect 10” round duct work to 10” round adapter.

3.Place cap over threaded end of external blower wiring and secure by turning clockwise.

2.Install threaded end of external blower wiring through external blower wiring knock out located inside the hood.

4.Connect 6 pin male connector from external blower wiring to 6 pin female connector on control board wire inside hood. Secure green ground wire from external blower wiring to ground screw on hood.

CBE-1000: WIRING DIAGRAM

 

White (common)

External Blower

Black (high)

Wiring Box

Blue (med)

(hood)

Red (low)

 

Green (ground)

Junction Box

(CBE-1000)

NOTE: For instructions on mounting the external blower, please refer to the CBE-1000 manual included

in the external blower packaging and on our website: www.zephyronline.com