5

Status Registers & Result Codes

 

Register

 

Dec.

Function & Description

Default

S0=

 

0 - 255

Set the number of the rings required before the modem

000

 

 

 

automatically answers a call. Set “S0=0” to disable auto-

 

 

 

 

answer mode.

 

S1=

 

0 - 255

Count the incoming rings and store the value to this register.

000

 

 

 

The value of this register is incremented with each ring. If no

 

 

 

 

rings occur over an 8 sec. interval, this register is cleared.

 

 

 

 

User can read but should not change this value.

 

S2=

 

0 - 255

S2 holds the decimal value of the ASCII character used as

043

 

 

 

the escape character. The default value (043) corresponds to

 

 

 

 

an ASCII character “+”. A value of 128 to 255 disables the

 

 

 

 

escape process, i.e., no escape character will be recognized.

 

S3=

 

0 - 127

Hold the decimal value of the Carriage Return <CR>

013

 

 

 

character used as the command line and result code

 

 

 

 

terminator. Pertain to asynchronous operation only.

 

S4=

 

0 - 127

Hold the decimal value of the character recognized as a line

010

 

 

 

feed. The line feed control character is output after the

 

 

 

 

carriage return control character if verbose result code are

 

 

 

 

used.

 

S5=

 

0 - 32,

Hold the decimal value of the character recognized as a

008

 

 

127

backspace. The modem will not recognize the backspace

 

 

 

 

character if this register is set to a value greater than 32.

 

S6=

 

 

Set the length of time, in seconds, that the modem must wait

 

 

 

 

(minimum 2 seconds even if the value is less than 2) after

 

 

 

 

going off-hook before dialing the first digit of the telephone

 

 

 

 

number.

 

 

 

2 - 65

For international version.

002

 

 

4 - 65

For Japanese version.

004

S7=

 

 

Set the time, in seconds, that the modem must wait before

 

 

 

 

hanging up because carrier is not detected.

 

 

 

1 - 255

For international version.

050

 

 

35 - 59

For Japanese version.

050

S8=

 

0 - 65

Set the time, in seconds, that the modem must pause when

002

 

 

 

the “,” dial modifier is encountered in the dial string.

 

S10=

 

1 - 255

Set the length of time, in tenths of a second, that the modem

020

 

 

 

waits before hanging up after a loss of carrier.

 

S11=

 

50 - 150

DTMF duration and inter digit delay. Set the duration and

095

 

 

 

spacing, in mini-seconds, in DTMF touch tine dialing.

 

S12=

 

0 - 255

Define the maximum period, in 2-hundredths of a second,

050

 

 

 

allowed between consecutive asynchronous escape character

 

 

 

 

“+” (plus) for the escape sequence to be considered valid.

 

S28=

 

0 - 255

V.34 modulation en-/disabler. 0: disabled. 1- 255: enabled.

001

S30=

 

0 - 90

Inactivity timer. Set the length of time, in minutes, that the

000

 

 

 

modem counts when there is no data flow in or out the DTE

 

 

 

 

serial port. A connection is disengaged when the counter

 

 

 

 

reaches the preset value. Set S30 =0 to disable the inactivity

 

 

 

 

timer. For buffer mode only.

 

S36=

 

 

Negotiation fallback options.

007

Status Registers & Result Codes 27