User's Guide for ZyXEL Omni 56K USB Modem
3-12
Enter the original password and a new password and then to re-enter the new password for
verification. For example:
PASSWORD (Enter supervisor password)
********
PASSWORD (Enter new supervisor password)
********
Verify (Enter the new supervisor password again)
********
OK
The command AT*Hn modifies the nth user password and the supervisor password on the
screen for viewing. Again, enter the supervisor password first.
The following commands enable different types and levels of security:
CODE DESCRIPTION
*G0 Disables security function.
*G1 Enables type 1 and level 1 security, with password check.
*G2 Enables type 1 and level 2 security, with password check and call-back.
*G3 Enables type 1 and level 1 security, with password check.
*G4 Enables type 1 and level 2 security, with password check and call-back.
*G5 Enables type 2 and level 2 security, with password check and call-back,
remote site enters the call-back number.
NOTE: Before the security type or level can be changed, the
modem requires the supervisor password.
For type 2 security, the remote site prompts you to enter the user password. A maximum of
three tries in 40 seconds is allowed. If a correct password is not entered within this time limit,
the line is disconnected. If the remote site is to enter the call-back number, it prompts you to
do so.