User's Guide for ZyXEL Omni 56K USB Modem

5-14

COMMAND DESCRIPTION VALUE
Minimum phase C speed parameter:
2400 bps. n=0
4800 bps. n=1
7200 bps. n=2
9600 bps. n=3
12000 bps. n=4
+FMINSP=n
14400 bps. n=5
+FPHCTO=
<value> DTE Phase C response time-out:
Determine how long the DCE waits for a command after reaching
the end of data when transmitting in Phase C.
<value>=0 to 255; 100 ms units.
0 to 255
Page transfer status:
Received page good. n=1
Page bad; retrain requested. n=2
Page good; retrain requested. n=3
Page bad; procedure interrupt requested. n=4
+FPTS=n
Page good; procedure interrupt requested. n=5
Phase C received EOL alignment:
The EOL patterns are bit aligned as received. n=0
+FREL=n
The last received bits of EOL patterns are byte aligned by the
DCE, with necessary zero fill bits inserted. Refer to TIA
(Telecommunications Industry Association) PN-2388 for details.
n=1
+FREV? Request the DCE revision identification.
"Enable polling" command:
Disable polling. n=0
+FSPL=n
Enable polling. n=1
All other +F commands are not supported, but the modem responds OK. In many casesthis means "it is ignored”.

Table 19. Class 2 Command Responses

RESPONSE VALUE FUNCTION AND DESCRIPTION
+FCFR Confirmation.
+FCIG:"string" Report remote ID response CIG.
+FCON Facsimile connection response.
+FCSI:"string" Report remote ID response CSI.
+FDCS:vr, br, wd, ln,
df, ec, bf, st Report session parameters response; refer to
+FDCC=.... command.
+FDIS:vr, br, wd, ln,
df, ec, bf, st Report session negotiation parameters
response; refer to +FDCC=.... command.
+FDTC:vr, br, wd, ln,
df, ec, bf, st Report remote capabilities response; refer to
+FDCC=.... command.
+FET:n Post page message response; refer to the
+FET=n command.
+FHNG:n Call termination status response: