CHEMICAL BALANCE

RULE: 7.4 to 7.6 is a desirable pH range. It is essential to maintain correct pH, see Table 15.

POOL AND SPA WATER

Your Pentair Pool Products pool heater was designed specifically for your spa or pool and will give you many years of trouble-free service, provided you keep your water chemistry in proper condition.

Three major items that can cause problems with your pool heater are: improper pH, disinfectant residual, and total alkalinity. These items, if not kept properly balanced, can shorten the life of the heater and cause permanent damage.

CAUTION

Heat exchanger damage resulting from chemical imbalance is not covered by the warranty.

WHAT A DISINFECTANT DOES

Two pool guests you do not want are algae and bacteria. To get rid of them and make pool water sanitary for swimming - as well as to improve the water's taste, odor and clarity - some sort of disinfectant must be used.

Chlorine and bromine are universally approved by health authorities and are accepted disinfecting agents for bacteria control.

WHAT IS A DISINFECTANT

RESIDUAL?

When you add chlorine or bromine to the pool water, a portion of the disinfectant will be consumed in the process of destroying bacteria, algae and other oxidizable materials. The disinfectant remaining is called chlorine residual or bromine residual. You can determine the disinfectant residual of your pool water with a reliable test kit, available from your local pool supply store.

You must maintain a disinfectant residual level adequate enough to assure a continuous kill of bacteria or virus introduced into pool water by swimmers, through the air, from dust, rain or other sources.

It is wise to test pool water regularly. Never allow chlorine residual to drop below 0.6 ppm (parts per million). The minimum level for effective chlorine or bromine residual is 1.4 ppm.

pH - The term pH refers to the acid/alkaline balance of water expressed on a numerical scale from 0 to 14. A test kit for measuring pH balance of your pool water is available from your local pool supply store; see Table 14.

Table 14.

 

 

 

pH Chart

 

 

 

 

 

 

 

 

 

 

 

 

Strongly Acid

 

 

 

Neutral

 

Strongly Alkaline

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Muriatic Acid has a pH of about 0. Pure water is 7 (neutral). Weak Lye solution have a pH of 13-14.

If pH becomes too high (over alkaline), it has these effects:

1.Greatly lowers the ability of chlorine to destroy bacteria and algae.

2.Water becomes cloudy.

3.There is more danger of scale formation on the plaster or in the heat exchanger tubing.

4.Filter elements may become blocked.

If pH is too low (over acid) the following conditions may occur:

1.Excessive eye burn or skin irritation.

2.Etching of the plaster.

3.Corrosion of metal fixtures in the filtration and recirculation system, which may create brown, blue, green, or sometimes almost black stains on the plaster.

4.Corrosion of copper tubes in the heater, which may cause leaks.

5.If you have a sand and gravel filter, the alum used as a filter aid may dissolve and pass through the filter.

CAUTION: Do not test for pH when the chlorine residual is 3.0 ppm or higher, or bromine residual is 6.0 ppm or higher. See your local pool supply store for help in properly balancing your water chemistry.

RULE: Chemicals that are acid lower pH. Chemicals that are alkaline raise pH.

Table 15.

 

pH Control Chart

 

 

 

 

 

 

 

 

 

 

 

 

6.8

7.0

7.2

7.4

7.6

7.8

8.0

8.2

8.4

Add Soda, Ash or

Marginal

Ideal

Marginal

Add Acid

Sodium Bicarbonate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALKALINITY High or Low:

"Total alkalinity" is a measurement of the total amount of alkaline chemicals in the water, and control pH to a great degree. (It is not the same as pH which refers merely to the relative alkalinity/acidity balance.) Your pool water's total alkalinity should be 100 - 140 ppm to permit easier pH control.

A total alkalinity test is simple to perform with a reliable test kit. You will need to test about once a week and make proper adjustments until alkalinity is in the proper range. Then, test only once every month or so to be sure it is being maintained. See your local pool dealer for help in properly balancing the water chemistry.

P/N 472235

Rev. E 4-15-05

Image 32
Contents MiniMax NT Series Customer Service Table of Contents Heater Identification Information Heater Identification Information HINWarranty Information Important NoticesConsumer Information and Safety Code RequirementsInstallation Instructions SpecificationsBelow Pool Installation Below or Above Pool InstallationPlumbing Connections ValvesWater Connections Reversing HeadersReversible Inlet/Outlet Connection, cont’d Sediment Traps GAS Line InstallationsGAS Connections GAS Pipe Sizing Pipe Sizing for GAS Line ConnectionsTesting GAS Pressure GAS Pressure RequirementsIndoor Venting General Requirements Indoor Installation USA only Outdoor Shelter Installation CanadaFits ALL Models Combustion AIR SupplyVent Adaptors Indoor Installations Minimax NT Venting Guidelines Outdoor Installation Venting Guidelines Side View Outdoor Vent KITElectrical Rating 60 Hz 120 / 240 Volts AC, single phase Electrical ConnectionsWiring DIAGRAM-NT STD & TSI with Ddtc MiniMax NT TSI & STD W/DDTC Wiring DiagramBasic System Operation Minimax NT HSI Electronic Ignition LIGHTING/OPERATIONSafety Controls Vacuum AIR Pressure FAN SwitchWater Pressure Switch Thermal FuseHeat Mode High LimitsOperation of Ignition Module Failure to Light the BURNER-LOCK OUTDigital Display Temperature Controller Ddtc System Indicator LightsSection IV. Operation SET UP Temperature Setting Troubleshooting Instruction Troubleshooting DdtcTroubleshooting General Service CHECKS-IGNITION ModuleMaintenance Instruction Energy Saving TipsSpring and Fall Operation Winter OperationChemical Balance Pool and SPA WaterReplacement Parts For Stdonly onlyRev. E Rev. E NT TSI w/DDTC 400 Model Starting w/Serial No Rev. E Rev. E Rev. E Pentair Water Pool and Spa, Inc Guide Dinstallation ET DE Fonctionnement Chauffe-eau pour piscine et spa MiniMax NTService Clients Table des matières Information Pour Lidentification DU CHAUFFE-EAU Information Pour Lidentification DU CHAUFFE-EAUConsignes Importantes GarantieInformation ET Recommandations À Lintention DU Consommateur Conformité AUX CodesConsignes dinstallations SpécificationsDérivation Manuelle Raccords DE PlomberieSoupapes Raccordements DES Conduites Deau Collecteurs réversiblesRaccords dentrée et de sortie réversibles, suite Collecteurs DE Sédiment Installations DE LA Conduite DE GAZRaccordement DES Conduites DE GAZ Dimension DES Tuyaux DE GAZ Mesure DES Tuyaux Pour Raccords D’ARRIVÉE DE GAZVérification DE LA Pression DE GAZ Le côté admission de la soupape de gazVentilation Intérieur Exigences Générales Installation Intérieure États-Unis Uniquement Convient À Tous LES Modèles Admission Dair DE CombustionAdaptateurs Daération Conseils Pour Linstallation Intérieur DU Minimax NT Ensemble DE Ventilation Pour Lextérieur Terminaison de la ventilationRaccordements Électriques Classement électrique 60 Hz 120/240 Volts c.a. monophaséWire Color Couleur DU Cable Consignes de Fonctionnement Fonctionnement Générale DU SystèmeContrôles DE Sécurité Commutateur Ventilateur DE Pression DU Vide DairCommutateur DE Pression Deau Fusible ThermiqueMode Chaleur Hautes LimitesVerrouillage EN CAS Déchec Dallumage Échec DE LA Flamme RallumageThermostat À Affichage Numérique Témoins Indicateurs DU SystèmeSection IV. Fonctionnement Réglage DU Thermostat Réglage DE LA Temperature Consignes DE Dépannage Dépannage Thermostat a Affichage NumeriqueConsignes DE Dépannage Verifications Dentretien Module DallumageConseils Pour Économies Dénergie Soupape DE SurpressionFonctionnement AU Printemps ET EN Automne Fonctionnement EN HiverÉquilibre Chimique DE Leau EAU DE Piscine ET DE SPAPièces DE Remplacement OnlyRev. E Pièces de Rechange pour La Série de Pièces DE Remplacement Rev. E Annote Annote Veuillez Concerver CE Guide Dinstruction

NT Series specifications

Pentair is a renowned name in the realm of water filtration and fluid management solutions, and the NT Series stands out as a key player in their extensive product lineup. Engineered for optimal performance and reliability, the NT Series showcases innovative features and technologies that cater to various water treatment needs.

One of the defining characteristics of the Pentair NT Series is its exceptional filtration capabilities. These filters are designed to effectively remove sediments, chlorine taste and odor, and other contaminants, ensuring clean and safe drinking water. With a multi-stage filtration process, the NT Series utilizes advanced materials and technologies that enhance filtration efficiency and longevity.

The NT Series is equipped with advanced filter media that can capture particles as small as 0.5 microns. This level of filtration is essential for households and commercial applications, where water quality is paramount. The filters are also designed for easy replacement, ensuring minimal downtime and ease of maintenance for users.

Another prominent feature of the NT Series is its compact design, making it suitable for various installation spaces. The filters are engineered to maximize flow rate while maintaining high filtration efficiency, ensuring that users do not experience reduced water pressure. This balance of performance and design is integral, especially in demanding applications.

Moreover, the NT Series incorporates innovative technology to monitor filter life and performance. Several models come with built-in sensors that provide real-time data on filter conditions, allowing users to know when it's time for a replacement. This proactive approach to maintenance enhances user experience and ensures continued access to high-quality water.

The materials used in the NT Series are also noteworthy. Constructed from durable, corrosion-resistant components, these filters are designed to withstand harsh operating conditions while maintaining peak performance over time. This enhances the overall lifespan of the product, providing users with a reliable and long-lasting solution for their water filtration needs.

In summary, the Pentair NT Series represents a blend of advanced filtration technology, user-friendly design, and durable construction. With its ability to remove various contaminants, easy maintenance features, and compact design, the NT Series caters to residential and commercial users alike. Investing in the NT Series ensures access to clean, great-tasting water while enjoying the benefits of reliable and efficient filtration technology.