Pentair NT Series Dimension DES Tuyaux DE GAZ, Mesure DES Tuyaux Pour Raccords D’ARRIVÉE DE GAZ

Page 52

Section III. Installation

52

DIMENSION DES TUYAUX DE GAZ

Tableau 2.

MESURE DES TUYAUX POUR RACCORDS D’ARRIVÉE DE GAZ

LONGUEUR MAXIMUM ÉQUIVALENTE DE TUYAUX (en mêtre)

Gaz Naturel à 1000 B.T.U. par pied cube

Propane à 2500 B.T.U. par pied cube

 

1.27 cm

1.905 cm

2.54 cm

3.175 cm

3.81 cm

5.08 cm

6.35 cm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODÉLE

NAT

PRO

NAT

PRO

NAT

PRO

NAT

PRO

NAT

PRO

NAT

PRO

NAT

PRO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

-

6m

9m

24m

40m

75m

140m

180m

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250

-

3m

6m

15m

21m

45m

75m

150m

180m

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

-

-

3m

9m

15m

30m

60m

110m

120m

180m

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

-

-

-

3m

6m

18m

30m

45m

60m

140m

120m

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RÉGULATION DU GAZ PROPANE EN DEUX PHASES POUR INSTALLATIONS RÉSIDENTIELLES

Dans plusieurs installations de conduites de gaz propane résidentielle, le fournisseur de gaz et/ou l'installateur utilisera un procédé de régulation en deux phases qui consiste tout d'abord à installer la 1ère phase du régulateur de gaz au réservoir, à une pression plus élevée, habituellement 10 PSI [68,9 kPa]. Une pression plus élevée permet de couvrir une plus grande distance avec des tuyaux de plus petite dimension. Puis, à une courte distance du chauffe-eau, habituellement à environ 24 pouces (60cm), ils installeront un second régulateur, la seconde phase, qui sera réglé à la pression d'entrée requise pour le chauffe-eau.

Voir les « Tables des spécifications concernant la pression de gaz »

Mesure des tuyaux pour gaz à haute pression 1ere phase

10 PSI [68.9 kPa] à 2500 B.T.U par pied cube

LONGUEUR MAXIMUM ÉQUIVALENTE DE TUYAUX

MODÈLE

0 pour 15 m

15 pour 30 m

30 pour 45 m

 

 

 

 

DE 200 À 400

1.27 cm

1.27 cm

1.27 cm

 

 

 

 

 

 

 

Tableau 3.

Mesure des tuyaux pour gaz à basse pression 2eme phase

2eme phase réglée à 14 po w.c.

LONGUEUR MAXIMUM ÉQUIVALENTE DE TUYAUX

MODÈLE

0 pour 3 m

3 pour 6 m

 

 

 

DE 200 À 400

1.905 cm

1.905 cm

 

 

 

 

 

Tableau 4.

RÉGULATION DU GAZ NATUREL EN DEUX PHASES POUR INSTALLATIONS RÉSIDENTIELLES

Dans plusieurs installations de conduites de gaz naturel résidentielles, le fournisseur de gaz et/ou l'installateur utilisera un procédé de régulation en deux phases qui consiste tout d'abord à installer la 1ère phase du régulateur de gaz à l'entrée principale, à une pression plus élevée. Une pression plus élevée, généralement réglée à 2 psi [13,79 kPa] ou 5 psi [34,47 kPa], permet de couvrir une plus grande distance avec des tuyaux de plus petite dimension. Puis, à une courte distance du chauffe-eau, habituellement à environ 24 pouces (60cm), ils installeront un second régulateur, la seconde phase. Ce second régulateur sera réglé à la pression d'entrée minimale requise pour le fonctionnement du chauffe-eau. Pour les chauffe-eau pour piscine de Pentair le minimum est de 7 pouces w.c. (ou 1,73 kPa).

Voir les « Tables des spécifications concernant la pression de gaz »

Mesure des tuyaux pour gaz à haute pression 1ere phase

2 PSI [13,79 kPa] à 1000 B.T.U par pied cube

LONGUEUR MAXIMUM ÉQUIVALENTE DE TUYAUX

MODÈLE

0 pour 15 m

15 pour 30 m

30 pour 45 m

 

 

 

 

DE 200 À 300

1.27 cm

1.27 cm

1.27 cm

 

 

 

 

400

1.905 cm

1.905 cm

1.905 cm

 

 

 

 

5 PSI [34,47 kPa] à 1000 B.T.U par pied cube

 

 

 

 

DE 200 À 400

1.27 cm

1.27 cm

1.27 cm

 

 

 

 

 

 

 

Tableau 5.

Mesure des tuyaux pour gaz à basse pression 2eme phase

2eme phase réglée à 7 po w.c.

LONGUEUR MAXIMUM ÉQUIVALENTE DE TUYAUX

MODÈLE

0 pour 3 m

3 pour 6 m

 

 

 

DE 200 À 300

1.905 cm

1.905 cm

 

 

 

400

1.905 cm

2.54 cm

 

 

 

2eme phase réglée à 7 po w.c.

DE 200 À 400

1.905 cm

2.54 cm

 

 

 

Tableau 6.

P/N 472235

Rev. E 4-15-05

Image 52
Contents MiniMax NT Series Customer Service Table of Contents Heater Identification Information Heater Identification Information HINWarranty Information Important NoticesConsumer Information and Safety Code RequirementsInstallation Instructions SpecificationsBelow Pool Installation Below or Above Pool InstallationPlumbing Connections ValvesWater Connections Reversing HeadersReversible Inlet/Outlet Connection, cont’d GAS Connections GAS Line InstallationsSediment Traps GAS Pipe Sizing Pipe Sizing for GAS Line ConnectionsTesting GAS Pressure GAS Pressure RequirementsIndoor Venting General Requirements Indoor Installation USA only Outdoor Shelter Installation CanadaVent Adaptors Combustion AIR SupplyFits ALL Models Indoor Installations Minimax NT Venting Guidelines Outdoor Installation Venting Guidelines Side View Outdoor Vent KITElectrical Rating 60 Hz 120 / 240 Volts AC, single phase Electrical ConnectionsWiring DIAGRAM-NT STD & TSI with Ddtc MiniMax NT TSI & STD W/DDTC Wiring DiagramBasic System Operation Minimax NT HSI Electronic Ignition LIGHTING/OPERATIONSafety Controls Vacuum AIR Pressure FAN SwitchWater Pressure Switch Thermal FuseHeat Mode High LimitsOperation of Ignition Module Failure to Light the BURNER-LOCK OUTDigital Display Temperature Controller Ddtc System Indicator LightsSection IV. Operation SET UP Temperature Setting Troubleshooting Instruction Troubleshooting DdtcTroubleshooting General Service CHECKS-IGNITION ModuleMaintenance Instruction Energy Saving TipsSpring and Fall Operation Winter OperationChemical Balance Pool and SPA WaterReplacement Parts For Stdonly onlyRev. E Rev. E NT TSI w/DDTC 400 Model Starting w/Serial No Rev. E Rev. E Rev. E Pentair Water Pool and Spa, Inc Guide Dinstallation ET DE Fonctionnement Chauffe-eau pour piscine et spa MiniMax NTService Clients Table des matières Information Pour Lidentification DU CHAUFFE-EAU Information Pour Lidentification DU CHAUFFE-EAUConsignes Importantes GarantieInformation ET Recommandations À Lintention DU Consommateur Conformité AUX CodesConsignes dinstallations SpécificationsSoupapes Raccords DE PlomberieDérivation Manuelle Raccordements DES Conduites Deau Collecteurs réversiblesRaccords dentrée et de sortie réversibles, suite Raccordement DES Conduites DE GAZ Installations DE LA Conduite DE GAZCollecteurs DE Sédiment Dimension DES Tuyaux DE GAZ Mesure DES Tuyaux Pour Raccords D’ARRIVÉE DE GAZVérification DE LA Pression DE GAZ Le côté admission de la soupape de gazVentilation Intérieur Exigences Générales Installation Intérieure États-Unis Uniquement Adaptateurs Daération Admission Dair DE CombustionConvient À Tous LES Modèles Conseils Pour Linstallation Intérieur DU Minimax NT Ensemble DE Ventilation Pour Lextérieur Terminaison de la ventilationRaccordements Électriques Classement électrique 60 Hz 120/240 Volts c.a. monophaséWire Color Couleur DU Cable Consignes de Fonctionnement Fonctionnement Générale DU SystèmeContrôles DE Sécurité Commutateur Ventilateur DE Pression DU Vide DairCommutateur DE Pression Deau Fusible ThermiqueMode Chaleur Hautes LimitesVerrouillage EN CAS Déchec Dallumage Échec DE LA Flamme RallumageThermostat À Affichage Numérique Témoins Indicateurs DU SystèmeSection IV. Fonctionnement Réglage DU Thermostat Réglage DE LA Temperature Consignes DE Dépannage Dépannage Thermostat a Affichage NumeriqueConsignes DE Dépannage Verifications Dentretien Module DallumageConseils Pour Économies Dénergie Soupape DE SurpressionFonctionnement AU Printemps ET EN Automne Fonctionnement EN HiverÉquilibre Chimique DE Leau EAU DE Piscine ET DE SPAPièces DE Remplacement OnlyRev. E Pièces de Rechange pour La Série de Pièces DE Remplacement Rev. E Annote Annote Veuillez Concerver CE Guide Dinstruction

NT Series specifications

Pentair is a renowned name in the realm of water filtration and fluid management solutions, and the NT Series stands out as a key player in their extensive product lineup. Engineered for optimal performance and reliability, the NT Series showcases innovative features and technologies that cater to various water treatment needs.

One of the defining characteristics of the Pentair NT Series is its exceptional filtration capabilities. These filters are designed to effectively remove sediments, chlorine taste and odor, and other contaminants, ensuring clean and safe drinking water. With a multi-stage filtration process, the NT Series utilizes advanced materials and technologies that enhance filtration efficiency and longevity.

The NT Series is equipped with advanced filter media that can capture particles as small as 0.5 microns. This level of filtration is essential for households and commercial applications, where water quality is paramount. The filters are also designed for easy replacement, ensuring minimal downtime and ease of maintenance for users.

Another prominent feature of the NT Series is its compact design, making it suitable for various installation spaces. The filters are engineered to maximize flow rate while maintaining high filtration efficiency, ensuring that users do not experience reduced water pressure. This balance of performance and design is integral, especially in demanding applications.

Moreover, the NT Series incorporates innovative technology to monitor filter life and performance. Several models come with built-in sensors that provide real-time data on filter conditions, allowing users to know when it's time for a replacement. This proactive approach to maintenance enhances user experience and ensures continued access to high-quality water.

The materials used in the NT Series are also noteworthy. Constructed from durable, corrosion-resistant components, these filters are designed to withstand harsh operating conditions while maintaining peak performance over time. This enhances the overall lifespan of the product, providing users with a reliable and long-lasting solution for their water filtration needs.

In summary, the Pentair NT Series represents a blend of advanced filtration technology, user-friendly design, and durable construction. With its ability to remove various contaminants, easy maintenance features, and compact design, the NT Series caters to residential and commercial users alike. Investing in the NT Series ensures access to clean, great-tasting water while enjoying the benefits of reliable and efficient filtration technology.