Electrical Rating 60 Hz

120 / 240 Volts AC, single phase

CAUTION

This heater is designed to operate at 120 or 240 VAC. It is not recommended to be connected to OR operate on a 208 VAC.

NOTE

The MiniMax NT heater is prewired for 240-volt AC connection using the “RED” connector and the “BEIGE” common connector; see Figure 16 below. For 120-volt AC supply, remove the “BEIGE” common connector and plug it into the “BLUE” common connector.

When connecting the power supply to the “Line Terminal Block” inside the junction box, follow the polarity as shown below. Connecting to 120 VAC, make sure that you connect the wire to the terminal (L), the neutral wire is connected to the neutral terminal (N) and the ground is connected to the ground terminal (GND); see below, Figure 17.

If any of the original wiring supplied with this heater must be replaced, installer must supply (No. 18 AWG, 600V, 105° C. U.L. approved AWM low energy stranded) copper wire or it’s equivalent. Thermal fuse wiring must be replaced with 18 AWG, 600V, 150° C. temp. rating.

CAUTION

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1, Natural Gas and Propane Installation Codes. If an external electrical source is utilized, the heater, when installed, must be electrically grounded and bonded in accordance with local codes or, in the absence of local codes, in the USA, with the National Electrical Code, ANSI/NFPA 7; in Canada, with Canadian Electric Code, CSA C22.1.

Always use crimp type connectors when connecting two wires.

 

TRANSFORMER

 

 

 

 

CONNECTOR

 

BLUE

 

 

 

 

120V CONNECTOR

 

 

 

 

 

 

 

 

BEIGE

 

 

 

 

 

 

 

 

COMMON CONNECTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TERMINAL BLOCK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR AC INPUT

 

You need to open the right

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120 / 240 VOLT SINGLE

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHASE "See Below"

 

door then remove the

 

 

240V CONNECTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 16.

 

 

 

 

 

control panel cover for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

servicing the Line Terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LINE TERMINAL BLOCK

 

 

 

 

 

Block as shown in Figures

 

 

 

 

 

 

 

 

 

16 & 17, (see item 40 in the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

exploded view on page 33).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GROUND

 

 

 

 

 

GREEN WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INTERNAL FACTORY WIRES

WHITE WIRE

BLACK WIRE

N

L

NEUTRAL / WHITE 120 VAC LINE #1 FOR 240 VAC

HOT / BLACK 120 VAC

LINE #2 FOR 240 VAC

Figure 17.

Rev. E 4-15-05

P/N 472235

Image 19
Contents MiniMax NT Series Customer Service Table of Contents Heater Identification Information HIN Heater Identification InformationImportant Notices Warranty InformationCode Requirements Consumer Information and SafetySpecifications Installation InstructionsValves Below Pool InstallationBelow or Above Pool Installation Plumbing ConnectionsReversing Headers Water ConnectionsReversible Inlet/Outlet Connection, cont’d GAS Connections GAS Line InstallationsSediment Traps Pipe Sizing for GAS Line Connections GAS Pipe SizingGAS Pressure Requirements Testing GAS PressureIndoor Venting General Requirements Outdoor Shelter Installation Canada Indoor Installation USA onlyVent Adaptors Combustion AIR SupplyFits ALL Models Indoor Installations Minimax NT Venting Guidelines Outdoor Vent KIT Outdoor Installation Venting Guidelines Side ViewElectrical Connections Electrical Rating 60 Hz 120 / 240 Volts AC, single phaseMiniMax NT TSI & STD W/DDTC Wiring Diagram Wiring DIAGRAM-NT STD & TSI with DdtcMinimax NT HSI Electronic Ignition LIGHTING/OPERATION Basic System OperationThermal Fuse Safety ControlsVacuum AIR Pressure FAN Switch Water Pressure SwitchFailure to Light the BURNER-LOCK OUT Heat ModeHigh Limits Operation of Ignition ModuleSystem Indicator Lights Digital Display Temperature Controller DdtcSection IV. Operation SET UP Temperature Setting Troubleshooting Ddtc Troubleshooting InstructionService CHECKS-IGNITION Module Troubleshooting GeneralEnergy Saving Tips Maintenance InstructionWinter Operation Spring and Fall OperationPool and SPA Water Chemical BalanceFor Stdonly only Replacement PartsRev. E Rev. E NT TSI w/DDTC 400 Model Starting w/Serial No Rev. E Rev. E Rev. E Pentair Water Pool and Spa, Inc Chauffe-eau pour piscine et spa MiniMax NT Guide Dinstallation ET DE FonctionnementService Clients Table des matières Information Pour Lidentification DU CHAUFFE-EAU Information Pour Lidentification DU CHAUFFE-EAUGarantie Consignes ImportantesConformité AUX Codes Information ET Recommandations À Lintention DU ConsommateurSpécifications Consignes dinstallationsSoupapes Raccords DE PlomberieDérivation Manuelle Collecteurs réversibles Raccordements DES Conduites DeauRaccords dentrée et de sortie réversibles, suite Raccordement DES Conduites DE GAZ Installations DE LA Conduite DE GAZCollecteurs DE Sédiment Mesure DES Tuyaux Pour Raccords D’ARRIVÉE DE GAZ Dimension DES Tuyaux DE GAZLe côté admission de la soupape de gaz Vérification DE LA Pression DE GAZVentilation Intérieur Exigences Générales Installation Intérieure États-Unis Uniquement Adaptateurs Daération Admission Dair DE CombustionConvient À Tous LES Modèles Conseils Pour Linstallation Intérieur DU Minimax NT Terminaison de la ventilation Ensemble DE Ventilation Pour LextérieurClassement électrique 60 Hz 120/240 Volts c.a. monophasé Raccordements ÉlectriquesWire Color Couleur DU Cable Fonctionnement Générale DU Système Consignes de FonctionnementFusible Thermique Contrôles DE SécuritéCommutateur Ventilateur DE Pression DU Vide Dair Commutateur DE Pression DeauÉchec DE LA Flamme Rallumage Mode ChaleurHautes Limites Verrouillage EN CAS Déchec DallumageTémoins Indicateurs DU Système Thermostat À Affichage NumériqueSection IV. Fonctionnement Réglage DU Thermostat Réglage DE LA Temperature Dépannage Thermostat a Affichage Numerique Consignes DE DépannageVerifications Dentretien Module Dallumage Consignes DE DépannageSoupape DE Surpression Conseils Pour Économies DénergieFonctionnement EN Hiver Fonctionnement AU Printemps ET EN AutomneEAU DE Piscine ET DE SPA Équilibre Chimique DE LeauOnly Pièces DE RemplacementRev. E Pièces de Rechange pour La Série de Pièces DE Remplacement Rev. E Annote Annote Veuillez Concerver CE Guide Dinstruction

NT Series specifications

Pentair is a renowned name in the realm of water filtration and fluid management solutions, and the NT Series stands out as a key player in their extensive product lineup. Engineered for optimal performance and reliability, the NT Series showcases innovative features and technologies that cater to various water treatment needs.

One of the defining characteristics of the Pentair NT Series is its exceptional filtration capabilities. These filters are designed to effectively remove sediments, chlorine taste and odor, and other contaminants, ensuring clean and safe drinking water. With a multi-stage filtration process, the NT Series utilizes advanced materials and technologies that enhance filtration efficiency and longevity.

The NT Series is equipped with advanced filter media that can capture particles as small as 0.5 microns. This level of filtration is essential for households and commercial applications, where water quality is paramount. The filters are also designed for easy replacement, ensuring minimal downtime and ease of maintenance for users.

Another prominent feature of the NT Series is its compact design, making it suitable for various installation spaces. The filters are engineered to maximize flow rate while maintaining high filtration efficiency, ensuring that users do not experience reduced water pressure. This balance of performance and design is integral, especially in demanding applications.

Moreover, the NT Series incorporates innovative technology to monitor filter life and performance. Several models come with built-in sensors that provide real-time data on filter conditions, allowing users to know when it's time for a replacement. This proactive approach to maintenance enhances user experience and ensures continued access to high-quality water.

The materials used in the NT Series are also noteworthy. Constructed from durable, corrosion-resistant components, these filters are designed to withstand harsh operating conditions while maintaining peak performance over time. This enhances the overall lifespan of the product, providing users with a reliable and long-lasting solution for their water filtration needs.

In summary, the Pentair NT Series represents a blend of advanced filtration technology, user-friendly design, and durable construction. With its ability to remove various contaminants, easy maintenance features, and compact design, the NT Series caters to residential and commercial users alike. Investing in the NT Series ensures access to clean, great-tasting water while enjoying the benefits of reliable and efficient filtration technology.