Emerson ITR manual System Type Glycol Cooled, Drycooler 35C 95F Ambient, Glycol Pump 3-Phase kW hp

Models: ITR

1 74
Download 74 pages 51.84 Kb
Page 43
Image 43

 

 

 

System Data

Table 13 Liebert Challenger ITR glycol cooled data, 50 Hz (continued)

 

 

 

 

 

System Type

Glycol Cooled

GLYCOOL

 

 

 

Self-Contained

Split Systems

Self-Contained

 

 

 

 

 

Indoor Unit

BR 070WG

BR 059E

BM 058G

 

 

 

 

Infrared Humidifier - Standard

 

 

 

Capacity, kg/hr (lb/hr)

5 (11)

5 (11)

5 (11)

kW

4.8

4.8

4.8

 

 

 

 

Steam Generating Humidifier - Optional

 

 

 

Capacity, kg/hr (lb/hr)

5 (11)

5 (11)

5 (11)

kW

3.9

3.9

3.9

 

 

 

 

Filter Section - Efficiencies per ASHRAE 52.1 - Disposable Type

 

 

20% efficiencies available in 51mm (2") - Standard, or optional 102mm (4") depths; other optional 102mm (4") efficiencies

are: 30%, 40-45%, 60-65%

 

 

 

Nominal Size, mm (in)

724 x 749

724 x 749

724 x 749

(28.5 x 29.5)

(28.5 x 29.5)

(28.5 x 29.5)

 

Effective Surface Area, m2 (ft2)

2.2 (24.1)

2.2 (24.1)

2.2 (24.1)

Glycol Regulating Valve

 

 

 

Size, in

1

1

1

Econ-O-Valve

 

 

 

Size, in

-

-

1

 

 

 

 

Cv

-

-

13.9

System Data*

 

MC_68WG

 

Flow Rate, l/s (GPM)

1.1 (17.5)

1.3 (20)

1.1 (17.5)

 

 

 

 

Unit Volume, liters (gallons)

7.5 (2.0)

7.5 (2.0)

15.0 (4.0)

Pressure Drop, kPa (ft.)

56.4 (18.9)

111.9 (37.5)

152.5 (51.1)

 

 

 

 

Connection Sizes Challenger ITR Unit

 

 

 

Condenser Supply

1-1/8 OD Cu

 

1-1/8 OD Cu

Condenser Return

1-1/8 OD Cu

 

1-1/8 OD Cu

 

 

 

 

Liquid Line

 

1/2 OD Cu

 

 

 

 

 

Suction Line

 

1-1/8 CD Cu

 

Humidifier Supply Line

1/4 OD Cu

1/4 OD Cu

1/4 OD Cu

 

 

 

 

Condensate Drain Line

1/2 FPT

1/2 FPT

1/2 FPT

 

 

 

 

Connection Sizes Condensing Unit

 

 

 

Condenser Supply

 

1-1/8 OD Cu

 

 

 

 

 

Condenser Return

 

1-1/8 OD Cu

 

 

 

 

 

Liquid Line

 

1/2 OD Cu

 

Suction Line

 

1-1/8 CD Cu

 

 

 

 

 

Drycooler 35°C (95°F) Ambient*

 

 

 

Model Number

DSF112-3PH

DSF174-3PH

DSF112-3PH

Drycooler Connections

2

2

2

 

 

 

 

Volume, liters (gallons)

5.8 (22.0)

6.9 (26.2)

5.8 (22.0)

 

 

 

 

Pressure Drop, kPa (ft.)

7.2 (2.4)

9.2 (3.1)

7.2 (2.4)

Fan, kW (hp)

.56 (3/4)

.56 (3/4)

.56 (3/4)

 

 

 

 

Glycol Pump - 3-Phase kW (hp)

1.1 (1.5)

1.1 (1.5)

1.1 (1.5)

Head, kPa (ft.)

262.6 (88.0)

262.6 (88.0)

262.6 (88.0)

Pump Suction and Discharge NPT, female

1-1/4 & 3/4

1-1/4 & 3/4

1-1/4 & 3/4

 

 

 

 

* All data above is based on 40% ethylene glycol solution.

35

Page 43
Image 43