System Data

Table 11 Liebert Challenger ITR glycol cooled data, 60 Hz (continued)

 

 

 

 

 

 

System Type

Glycol Cooled

GLYCOOL

 

 

 

 

Self-Contained

 

Split Systems

Self-Contained

 

 

 

 

 

 

 

Indoor Unit

BR 071WG

 

BR 060E

BM 061G

Infrared Humidifier - Standard

 

 

 

 

Capacity, lb/hr (kg/hr)

11 (5)

 

11 (5)

11 (5)

 

 

 

 

 

kW

4.8

 

4.8

4.8

 

 

 

 

 

Steam Generating Humidifier - Optional

 

 

 

 

Capacity, lb/hr (kg/hr)

11 (5)

 

11 (5)

11 (5)

 

 

 

 

 

kW

3.9

 

3.9

3.9

Filter Section - Efficiencies per ASHRAE 52.1 - Disposable Type

 

 

20% efficiencies available in 2" (51mm) - Standard, or optional 4" (102mm) Depths; other optional 4" (102mm) efficiencies

are: 30%, 40-45%, 60-65%

 

 

 

 

Nominal Size, inches (mm)

28.5 x 29.5

 

28.5 x 29.5

28.5 x 29.5

(724 x 749)

 

(724 x 749)

(724 x 749)

 

 

Effective Surface Area, ft2 (m2)

24.1 (2.2)

 

24.1 (2.2)

24.1 (2.2)

Glycol Regulating Valve

 

 

 

 

Size, in

1

 

1

1

 

 

 

 

 

Econ-O-Valve

 

 

 

 

Size, in

 

1

 

 

 

 

 

Cv

 

13.9

 

 

 

 

 

System Data*

 

 

MC_*69WG

 

Flow Rate, GPM (l/s)

17.5 (1.1)

 

20 (1.3)

17.5 (1.1)

 

 

 

 

 

Unit Volume, gal (l)

2.0 (7.5)

 

2.0 (7.5)

4.0 (15.0)

 

 

 

 

 

Pressure Drop, ft. (kPa)

18.9 (56.4)

 

37.5 (111.9)

51.1 (152.5)

Connection Sizes Challenger ITR Unit

 

 

 

 

Condenser Supply

1-1/8 OD Cu

 

 

1-1/8 OD Cu

 

 

 

 

 

Condenser Return

1-1/8 OD Cu

 

 

1-1/8 OD Cu

Liquid Line

 

 

1/2 OD Cu

 

 

 

 

 

 

Suction Line

 

 

1-1/8 OD Cu

 

 

 

 

 

 

Humidifier Supply Line

1/4 OD Cu

 

1/4 OD Cu

1/4 OD Cu

Condensate Drain Line

1/2 FPT

 

1/2 FPT

1/2 FPT

 

 

 

 

 

Connection Sizes Condensing Unit

 

 

 

 

Condenser Supply

 

 

1-1/8 OD Cu

 

Condenser Return

 

 

1-1/8 OD Cu

 

 

 

 

 

 

Liquid Line

 

 

1/2 OD Cu

 

 

 

 

 

 

Suction Line

 

 

1-1/8 OD Cu

 

Drycooler 95°F (35°C) Ambient*

 

 

 

 

Model Number

DSF112-3PH

 

DSO174-3PH

DSO112-3PH

 

 

 

 

 

Drycooler Connections

2

 

2

2

Volume, gal. (l)

5.8 (22.0)

 

6.9 (26.2)

5.8 (22.0)

 

 

 

 

 

Pressure Drop, ft. (kPa)

2.4 (7.2)

 

3.1 (9.2)

2.4 (7.2)

 

 

 

 

 

Fan, hp (kW)

3/4 (.56)

 

3/4 (.56)

3/4 (.56)

Glycol Pump, 3-phase hp (kW)

3/4 (.56)

 

3/4 (.56)

1.5 (1.1)

Head, ft. (kPa)

69 (205.9)

 

69 (205.9)

88 (262.6)

 

 

 

 

 

Pump Suction and Discharge NPT, female

1-1/4 & 3/4

 

1-1/4 & 3/4

1-1/4 & 3/4

* All data above is based on 40% ethylene glycol solution.

33

Page 41
Image 41
Emerson ITR manual Indoor Unit, Steam Generating Humidifier Optional