Uniden BC75XLT owner manual Custom Search

Page 36

to the nearest valid frequency. For example, if you enter 151.473 (MHz), your scanner accepts it as 151.475. However, if you enter a frequency that is out of range, the scanner sounds an error tone and Error appears. Enter another frequency.

3.Press Srch. The scanner searches, starting from the frequency you just entered. (Turn the scroll control knob to change the search direction.) The scanner also automatically turns on the Delay function; DLY displays. To turn off the function, press Func + Dly (see page 47).

Custom Search

You can adjust each preset search range’s upper and lower frequency limits.

1.Press Func + Psrc. The scanner enters Custom Search mode and displays SRCH and PGM. The upper and lower frequencies for Custom Search range 1 alternate.

2.Turn the scroll control knob to scroll through the rest of Custom Search ranges until you find the one you want. The search range numbers at the top of the screen change as you cycle through them.

3.Enter the lower limit frequency and press E.. The

frequency range flashes with the adjusted lower limit frequency.

4.Enter the upper limit frequency and press E.. The

adjusted frequency range flashes with the adjusted upper limit frequency (both upper and lower frequencies are now adjusted).

36

Image 36
Contents BC75XLT Owner’s Precautions Page Contents Page Unlock Priority Delay Keylock Backlight PC Programming FCC Wants You to Know Scanning Legally Page BC75XLT Feature Highlights IntroductionPage Page Frequency Range Frequency Range MHz Step Mode kHz Transmission USA Band PlanStep Mode Transmission MHz KHz Canada Band Plan What is Scanning? What is Searching?Scanning basics Conventional Scanning Simplex OperationService Search Bands What Are Banks?Repeater Operation Channel Storage BanksWhere To Learn More Custom Search RangesSetup What’s In The Box?Setting Up the Scanner Connect the AntennaConnecting an Optional Extension Speaker Adjusting the Belt ClipConnect an Optional Earphone/Headphone Installing Non-Rechargeable Batteries Installing Rechargeable 2300mAh Ni-MH BatteriesCharging the Ni-MH Batteries through USB Connection LCD Message Batt Meaning Scanner Type Cond Low Battery Alert Turn On The ScannerAdjust Squelch Adjusting for InterferenceBC75XLT Controls and Display Hardware DescriptionKeypad Key/Icon Primary Function Key HoldKey/Icon Primary Function Key Scan Srch/SvcPri DlyKey/Icon Primary Function Key PSrc Pgm/EClr FuncLCD Display Line Display DescriptionTo Close Call mode Display DescriptionSearch Hold modes Operation SearchINGQuick Search Custom Search Service Search Storing Frequencies Scanning Erasing a Stored FrequencyPress Func + Pgm Enabling/Disabling Channel BanksScan the Stored Channels Manually Select a ChannelPage Close Call Operation Mode Close Call RF CaptureUsing Close Call Mode Band Range MHz To turn a Close Call Low HighLocking Out Channels and Frequencies Temporary Lock Out Permanent Lock OutUnlock You cannot lock out frequencies during WX service search PriorityDelay Mode Delay Specification KeylockBacklight PC ProgrammingTroubleshooting Problem Possible Cause SuggestionProblem Possible Cause Suggestion Problem Possible Cause Suggestion Care and Maintenance Resetting the ScannerGeneral Use LocationCleaning RepairsBirdies Page Specifications Seconds One-Year Limited Warranty Warrantor Uniden America Corporation UnidenProcedure for Obtaining Performance of Warranty