Uniden Guide on Programming and Storing Frequencies for Your Scanner

Page 38

Storing Frequencies

To store frequencies in the first available channel:

1.Press Hold.

2.Enter the frequency and press Hold and Func + Pgm..

3.The scanner alternates between the frequency you are stopped on and the first available channel number with no frequency stored. Press E.

4.The scanner is now on that frequency, on Hold with the Delay function automatically turned on (see page 47). Press Srch or Scan again to continue.

Note: Refer to www.radioreference.com for a list of frequencies in your area.

You can also store frequencies directly into a specific channel in a specific channel bank.

1.From Search or Scan modes, press Hold.

2.Press Func + Pgm. The scanner displays the next available channel number and alternates between O and the frequency you’re holding on.

3.Press Func and turn the scroll control knob to change channel banks if desired; press Func again to select that channel bank.

4.Turn the scroll control knob to change channels within that bank.

5.Press E to store the frequency in the displayed channel/ channel bank.

6.The scanner is now on that frequency, on Hold with the Delay function automatically turned on (see page 47).

38

Image 38
Contents BC75XLT Owner’s Precautions Page Contents Page Unlock Priority Delay Keylock Backlight PC Programming FCC Wants You to Know Scanning Legally Page BC75XLT Feature Highlights IntroductionPage Page Frequency Range Frequency Range MHz Step Mode kHz Transmission USA Band PlanStep Mode Transmission MHz KHz Canada Band Plan Scanning basics What is Scanning?What is Searching? Conventional Scanning Simplex OperationRepeater Operation Service Search BandsWhat Are Banks? Channel Storage BanksWhere To Learn More Custom Search RangesSetup What’s In The Box?Setting Up the Scanner Connect the AntennaConnect an Optional Earphone/Headphone Connecting an Optional Extension SpeakerAdjusting the Belt Clip Installing Non-Rechargeable Batteries Installing Rechargeable 2300mAh Ni-MH BatteriesCharging the Ni-MH Batteries through USB Connection LCD Message Batt Meaning Scanner Type Cond Low Battery Alert Turn On The ScannerAdjust Squelch Adjusting for InterferenceKeypad BC75XLT Controls and DisplayHardware Description Key/Icon Primary Function Key HoldPri Key/Icon Primary Function Key ScanSrch/Svc DlyClr Key/Icon Primary Function Key PSrcPgm/E FuncLCD Display Line Display DescriptionTo Close Call mode Display DescriptionSearch Hold modes Quick Search OperationSearchING Custom Search Service Search Storing Frequencies Press Func + Pgm ScanningErasing a Stored Frequency Enabling/Disabling Channel BanksScan the Stored Channels Manually Select a ChannelPage Close Call Operation Mode Close Call RF CaptureUsing Close Call Mode Band Range MHz To turn a Close Call Low HighLocking Out Channels and Frequencies Unlock Temporary Lock OutPermanent Lock Out You cannot lock out frequencies during WX service search PriorityDelay Mode Delay Specification KeylockBacklight PC ProgrammingTroubleshooting Problem Possible Cause SuggestionProblem Possible Cause Suggestion Problem Possible Cause Suggestion General Use Care and MaintenanceResetting the Scanner LocationBirdies CleaningRepairs Page Specifications Seconds One-Year Limited Warranty Warrantor Uniden America Corporation UnidenProcedure for Obtaining Performance of Warranty