Guidance and manufacturer’s declaration – electromagnetic immunity

The VPAP Adapt SV is intended for use in the electromagnetic environment specified below. The customer or the user of the VPAP Adapt SV should assure that it is used in such an environment.

 

IEC60601-1-2

Compliance

 

Electromagnetic

Immunity test

 

environment –

test level

level

 

 

 

guidance

 

 

 

 

 

 

 

 

 

Electrostatic

±6 kV contact

±6 kV contact

 

Floors should be wood,

discharge (ESD)

 

 

 

concrete or ceramic tile. If

IEC 61000-4-2

±8 kV air

±8 kV air

 

floors are covered with

 

 

 

 

synthetic material, the

 

 

 

 

relative humidity should be

 

 

 

 

at least 30%.

 

 

 

 

 

Electrical fast

±2 kV for power

±2 kV

 

Mains power quality should

transient/burst

supply lines

 

 

be that of a typical

IEC 61000-4-4

±1 kV for input/

Not Applicable

 

commercial or hospital

 

 

environment.

 

output lines

 

 

 

 

 

 

 

 

Surge

±1 kV differential

±1 kV differential

 

Mains power quality should

IEC 61000-4-5

mode

mode

 

be that of a typical

 

±2 kV common

±2 kV common

 

commercial or hospital

 

 

environment.

 

mode

mode

 

 

 

 

 

 

 

Voltage dips, short

<5% Ut

< 12V

 

Mains power quality should

interruptions and

(>95% dip in Ut)

(>95% dip in 240V)

 

be that of a typical

voltage variations on

for 0.5 cycle

for 0.5 cycle

 

commercial or hospital

power supply input

 

 

 

environment.

lines.

40% Ut

96V

 

If the user of the

IEC 61000-4-11

(60% dip in Ut)

(60% dip in 240V)

 

VPAP Adapt SV requires

 

for 5 cycles

for 5 cycles

 

continued operation during

 

70% Ut

168V

 

power mains interruptions,

 

 

it is recommended that the

 

(30% dip in Ut)

(30% dip in 240V)

 

VPAP Adapt SV be powered

 

for 25 cycles

for 25 cycles

 

from an uninterruptible

 

<5% Ut

<12V

 

power source.

 

 

 

 

(>95%dip in Ut)

(>95%dip in 240V)

 

 

 

for 5 sec

for 5 sec

 

 

 

 

 

 

 

Power frequency

3 A/m

3 A/m

 

Power frequency magnetic

(50/60 Hz)

 

 

 

fields should be at levels

magnetic field

 

 

 

characteristic of a typical

IEC 61000-4-8

 

 

 

location in a typical

 

 

 

 

commercial or hospital

 

 

 

 

environment

 

 

 

 

 

NOTE: Ut is the AC mains voltage prior to application of the test level.

 

 

 

 

 

 

(Continued next page)

English

Technical Specifications

37

Image 37
Contents Vpap Adapt SV Contents Vpap Adapt SV IntroductionUser/Owner Responsibility DefinitionsVpap Adapt SV Quick Setup Guide Vpap Adapt SV Components Vpap Adapt SV SystemConnect this end MasksConnect this end to To the mask Flow generatorAssembling the Vpap Adapt SV System Connect the power cordFront view of Vpap Adapt SV Attach the mask to the air tubingHumidifiers Connecting a HumidifierDo not tip the humidifier while it is connected to HumidAire 2i attached to the Vpap Adapt SV HumidAireHumidAire English Anti-bacterial Filter ResLinkSupplemental Oxygen Using DC Power to Run the Vpap Adapt SVStandby Mode Using the Vpap Adapt SVStarting Treatment Stopping TreatmentLCD screen Control Panel FunctionsStart/Stop key Up/Down keyAlarm LEDs and Alarm mute Adjusting SettingsLeft key green Right key redExample You wish to change the setting for the mask you are usingNavigating the Patient menu MenusMask Settings MenuLearn Circuit Results Menu Ramp Cpap mode onlySmartStop Leak AlertOptions Menu Servicing Menu Treatment ScreensLow Mask Pressure Alarm AlarmsIf a low pressure alarm sounds Triggered byHigh Pressure / High Average Pressure Alarms Power Fail AlarmFlow Blocked Alarm Insufficient Pressure Support AlarmHigh Leak Alert Daily Cleaning and MaintenanceWeekly Periodically Air tubing assembly removed for cleaningServicing Air FilterHypoallergenic Air Filter Fitting the filterServicing Australia and New Zealand TroubleshootingGlossary Technical Specifications Inspiratory Trigger Characteristics Alarm specificationsIEC 601-1 classifications Mass flow sensor Glossary of symbolsEmissions test Compliance Next Portable and mobile RF communications Separation distance according to frequency of transmitter Limited Warranty Index Index

VPAP Adapt SV specifications

The ResMed VPAP Adapt SV is a cutting-edge device designed to improve the quality of life for patients suffering from complex sleep apnea conditions, including central and obstructive sleep apnea. It combines advanced technology with user-friendly features to provide effective therapy while ensuring maximum comfort for users.

A standout feature of the VPAP Adapt SV is its Adaptive Servo-Ventilation (ASV) algorithm. This proprietary technology continuously monitors a patient’s breathing patterns and adjusts the airflow accordingly. By providing just the right amount of pressure support during inhalation and maintaining a minimal backup rate during exhalation, the device ensures optimal ventilation while minimizing the risk of over-ventilation. This responsiveness is crucial for patients who may experience fluctuating airway resistance and varying degrees of respiratory events.

The VPAP Adapt SV is equipped with a sophisticated data management system that tracks treatment progress in real time. It automatically collects information about usage, leak rates, and overall pressure settings, which can be easily accessed and reviewed by healthcare providers. This data-driven approach facilitates personalized treatment adjustments, empowering both patients and clinicians to make informed decisions.

Comfort is enhanced through various design features, including a quiet operation mechanism that minimizes noise disruption during sleep. The device offers a range of pressure settings that can be tailored to individual needs, allowing for a comfortable therapeutic experience. The VPAP Adapt SV is compatible with ResMed’s range of CPAP masks, which are ergonomically designed to fit securely without compromising comfort.

Another notable characteristic is its user-friendly interface, which simplifies the setup and adjustments needed for optimal therapy. Patients can easily navigate through various options on the bright display screen, making it accessible for users of all ages.

Additionally, the VPAP Adapt SV’s compact design makes it a portable option for those who travel frequently. It comes with a carrying case and can operate on both AC and DC power sources, ensuring that patients can maintain their therapy wherever they go.

In conclusion, the ResMed VPAP Adapt SV represents a significant advancement in respiratory therapy. With its Adaptive Servo-Ventilation technology, comprehensive data management, and focus on patient comfort, it provides a holistic approach to managing complex sleep apnea, making it a preferred choice for healthcare providers and patients alike.