ResMed VPAP Adapt SV manual Technical Specifications

Page 33

SmartStop

A feature that stops the VPAP Adapt SV automatically when you remove the mask. You can turn SmartStop on or off in the Settings menu.

Tidal volume

The volume of air, in liters, breathed in or out in one breath.

Technical Specifications

Dimensions (H x W x D)

5.6" x 9.8" x 11.5" (142 mm x 248 mm x 293 mm)

Weight

Flow generator with cover: 8.14 lbs (3.7 kg)

Flow generator with HumidAire 2i (empty): 9.24 lbs (4.2 kg)

Environmental conditions

Operating temperature: 41ºF to 95ºF (+5ºC to +35ºC)

Storage and transport temperature: -4ºF to +140ºF (-20ºC to +60ºC)

Humidity—operating, storage and transportation: 10%–95% non-condensing

Housing construction

Injection moulded plastic

Air tubing

1 x 6’6” (2 m)

Air filter

Synthetic fiber

Patient connection port

22 mm taper, compatible with ISO 5356-1:2004 Anaesthetic & Respiratory Equipment—Conical Connectors

Power supply

AC Input range: 110–120V and 220–240V; 50–60Hz; 60VA

DC Input range (if using DC Converter: 12–13.8V DC

Performance

Operating pressure range: 4–25 cm H2O

Sound pressure level

<30 dBA (tested in accordance with the requirements of ISO 17510-1)

Battery type

Lithium

English

Technical Specifications

33

Image 33
Contents Vpap Adapt SV Contents Vpap Adapt SV IntroductionUser/Owner Responsibility DefinitionsVpap Adapt SV Quick Setup Guide Vpap Adapt SV Components Vpap Adapt SV SystemConnect this end MasksConnect this end to To the mask Flow generatorAssembling the Vpap Adapt SV System Connect the power cordFront view of Vpap Adapt SV Attach the mask to the air tubingConnecting a Humidifier HumidifiersDo not tip the humidifier while it is connected to HumidAire 2i attached to the Vpap Adapt SV HumidAireHumidAire English Anti-bacterial Filter ResLinkSupplemental Oxygen Using DC Power to Run the Vpap Adapt SVStandby Mode Using the Vpap Adapt SVStarting Treatment Stopping TreatmentLCD screen Control Panel FunctionsStart/Stop key Up/Down keyAlarm LEDs and Alarm mute Adjusting SettingsLeft key green Right key redExample You wish to change the setting for the mask you are usingNavigating the Patient menu MenusSettings Menu MaskLearn Circuit Results Menu Ramp Cpap mode onlySmartStop Leak AlertOptions Menu Servicing Menu Treatment ScreensLow Mask Pressure Alarm AlarmsIf a low pressure alarm sounds Triggered byHigh Pressure / High Average Pressure Alarms Power Fail AlarmInsufficient Pressure Support Alarm Flow Blocked AlarmHigh Leak Alert Cleaning and Maintenance DailyWeekly Periodically Air tubing assembly removed for cleaningServicing Air FilterHypoallergenic Air Filter Fitting the filterServicing Australia and New Zealand TroubleshootingGlossary Technical Specifications Alarm specifications Inspiratory Trigger CharacteristicsIEC 601-1 classifications Mass flow sensor Glossary of symbolsEmissions test Compliance Next Portable and mobile RF communications Separation distance according to frequency of transmitter Limited Warranty Index Index

VPAP Adapt SV specifications

The ResMed VPAP Adapt SV is a cutting-edge device designed to improve the quality of life for patients suffering from complex sleep apnea conditions, including central and obstructive sleep apnea. It combines advanced technology with user-friendly features to provide effective therapy while ensuring maximum comfort for users.

A standout feature of the VPAP Adapt SV is its Adaptive Servo-Ventilation (ASV) algorithm. This proprietary technology continuously monitors a patient’s breathing patterns and adjusts the airflow accordingly. By providing just the right amount of pressure support during inhalation and maintaining a minimal backup rate during exhalation, the device ensures optimal ventilation while minimizing the risk of over-ventilation. This responsiveness is crucial for patients who may experience fluctuating airway resistance and varying degrees of respiratory events.

The VPAP Adapt SV is equipped with a sophisticated data management system that tracks treatment progress in real time. It automatically collects information about usage, leak rates, and overall pressure settings, which can be easily accessed and reviewed by healthcare providers. This data-driven approach facilitates personalized treatment adjustments, empowering both patients and clinicians to make informed decisions.

Comfort is enhanced through various design features, including a quiet operation mechanism that minimizes noise disruption during sleep. The device offers a range of pressure settings that can be tailored to individual needs, allowing for a comfortable therapeutic experience. The VPAP Adapt SV is compatible with ResMed’s range of CPAP masks, which are ergonomically designed to fit securely without compromising comfort.

Another notable characteristic is its user-friendly interface, which simplifies the setup and adjustments needed for optimal therapy. Patients can easily navigate through various options on the bright display screen, making it accessible for users of all ages.

Additionally, the VPAP Adapt SV’s compact design makes it a portable option for those who travel frequently. It comes with a carrying case and can operate on both AC and DC power sources, ensuring that patients can maintain their therapy wherever they go.

In conclusion, the ResMed VPAP Adapt SV represents a significant advancement in respiratory therapy. With its Adaptive Servo-Ventilation technology, comprehensive data management, and focus on patient comfort, it provides a holistic approach to managing complex sleep apnea, making it a preferred choice for healthcare providers and patients alike.