Initial Assembly & Installation
BI
D E
F
GH
J
N |
C | A | M |
| To Front |
B |
| |||
|
|
| ||
A. Control Valve |
|
|
| Tube |
|
|
|
| |
B. Cotter Pin |
|
| L |
|
C. Clevis Pin |
|
|
|
|
D. Control Lever |
|
|
|
|
E. |
|
|
|
|
F. Tall Fitting |
|
| K |
|
G. Short Fitting |
|
|
|
|
H. 1/2” x 75” Hose w/ Female Quick Connector |
| To Back | M | |
I. 1/2” x 75” Hose w/ Male Quick Connector |
| |||
| ||||
J. 23/32” x 40” Hose w/ Male Quick Connector |
|
| ||
| Tube |
| ||
K. 23/32” x 40” Hose w/ Female Quick Connector |
|
| ||
|
|
| ||
L. Female Quick Connector |
|
| L | |
M. Male Quick Connector |
|
|
|
|
N. Large Fitting |
|
|
|
|
Figure 26. Assemble Control Valve
Install Control Valve
1.Locate the old single spool master valve removed from tractor (A, Figure 26).
NOTE: From this point on, the old master valve will be referred to as the control valve (A, Figure 26).
2.Install the control lever (D, Figure 26) using a small clevis pin (C), the
3.Install a tall fitting (F, Figure 26) and a short fitting (G) into the control valve (A) as shown.
4.Install a male quick connector (M, Figure 26) on one of the 1/2” x 75” long hoses (I), and connect the other end of the hose to the tall fitting (F)
5.Install a female quick connector (L, Figure 26) on the other 1/2” x 75” long hose (H) and connect it to the short fitting (G).
NOTE: The quick connector ends of the 1/2” x 75” hoses attached to the control valve in steps 4 and 5 will be con- nected to the dozer hydraulic hoses later.
6.Install two large fittings (N, Figure 26) in the front of the control valve (A).
7.Install a male quick connector (M, Figure 26) on one of the 23/32” x 40” hoses (J) and a female quick con- nector (L) on the other 23/32” x 40” hose (K).
17