Check the Hydraulic Oil Level

Observe and Obey:

Only routine maintenance items specified in this manual shall be performed by the operator.

Scheduled maintenance inspections shall be completed by qualified service technicians, according to the manufacturer's specifications and the requirements specified in the responsibilities manual.

Maintenance Symbols Legend

The following symbols have been used in this manual to help communicate the intent of the instructions. When one or more of the symbols appear at the beginning of a maintenance procedure, it conveys the meaning below.

Indicates that tools will be required to perform this procedure.

Indicates that new parts will be required to perform this procedure.

Maintaining the hydraulic oil at the proper level is essential to machine operation. Improper hydraulic oil levels can damage hydraulic components. Daily checks allow the inspector to identify changes in oil level that might indicate the presence of hydraulic system problems.

1Be sure the boom is in the stowed position and the outriggers are retracted.

2Visually inspect the oil level in the hydraulic tank.

Result: The hydraulic oil level should be 3 inches / 7.6 cm from the top of tank.

Hydraulic oil specifications

Hydraulic oil type

Dexron equivalent

 

 

14

Genie TMZ-50/30 & Genie TMZ-17/10

Part No. 72896

Image 16
Contents Operator’s Manual Contents Contact usSafety Rules Do Not Operate UnlessElectrocution Hazards Tip-over HazardsBodily Injury Hazard Collision Hazards Component Damage HazardsLifting Hazards Explosion and Fire HazardsDamaged Machine Hazards Towing HazardsPersonnel Lifting Configuration Tip-over Hazards Material Lifting Configuration Collision HazardsFall Hazards Collision HazardOptional Drive System Tip over Hazards Decal LegendBattery Safety Burn Hazards Explosion HazardsTip-over Hazard Lifting HazardControls Platform Control PanelGround Control Panel Drive Control Panel option Pre-operation Inspection FundamentalsPre-operation Inspection PRE-OPERATION InspectionMaintenance Symbols Legend MaintenanceCheck the Hydraulic Oil Level Observe and Obey Check the Engine Oil Level Engine ModelsScheduled Maintenance Check the Tires and WheelsFunction Tests SetupFunction Tests At the Ground Controls Test Emergency StopTest Outrigger Interlock Test the Boom FunctionsAt the Platform Controls Test the HornTest Machine Functions Test the Drive and Steering If equippedWorkplace Inspection Workplace InspectionSet up Operating InstructionsEmergency Stop Only use the machine as it was intendedTransport Towing InformationModels with Engines Manual Lowering DC Models Manual LoweringPrimary boom retract function All other functionsOperation from Platform Operation from GroundTo Position Platform Optional Drive System Operating Instructions Backing Up with Trailer If equipped with surge brakeTransport Not attached to a tow vehicle After Each UseMaterial Lifting Configuration Observe and Obey Material Lifting Configuration Set upBattery and Charger Instructions Observe and Obey Dry Battery Filling Charging InstructionsTo Charge Battery Voltage ConversionDecals Decal InspectionDecals Specifications Reporting Safety Defects Reporting Safety DefectsGenie Industries PO Box Redmond, WA Distributed By