The
Example Setup
The default setup is 1 kHz, with zero delay and 100 us pulse on both channels. The pulse in not inverted and the pulse mode is in continuous pulse generation mode which means that pulse count is not available. By pressing the OUTPUT button on the front panel you will see these pulses on the respective outputs.
Turning the encoder with the pulses enabled and the unit will sweep the frequency on the fly, hitting the X10 button will bring you to 10 times the frequency. Pressing the down arrow twice will highlight the pulse width selection. Turn the encoder and the width will sweep. Try this with the polarity setting; it will change on the fly. Turn off the pulses.
Press MENU to continue to the settings for CHANNEL 2. Its default is the same as CHANNEL 1.
Hitting MENU again will bring up the OUTPUT MENU. This menu allows the unit to change pulse modes, disable and enable the outputs (depending on the pulse mode), choose internal or external trigger (depending on the pulse mode) and choose whether the sync is based off CHANNEL 1 or 2.
Hitting the arrow keys allows the user to decide which settings on the current menu they would like to adjust. Press the up arrow once to scroll around to the bottom of the menu or press the down arrow 5 times. The contrast setting will be highlighted.
Turn the encoder to adjust the contrast. The contrast will adjust “on the fly” and a question mark will appear at the end of the contrast. Hit ENTER and save the contrast saving into the
Page 4
© 2004 Directed Energy, Inc.