Directed Electronics PDG-2515/2520 manual Example Pulse Count Mode

Page 21

PDG-2515/2520 Operating Manual

The PULSE CT variable for each channel can be set to any value between 1 and 65,535. In setting the PULSE CT, the x10 button will increase this number by a factor of ten and the encoder wheel will increase/decrease the number of pulses incrementally by one. For example, to set the count to 1,500, first set the count to 15 using the encoder wheel, then press the X10 button two times. The first press will increment the count to 150, and the second to 1,500.

Pressing the OUTPUT button enables the output pulse series. The Pulse On LED will illuminate until the pulse series is completed, at which time the LED will extinguish. Each time the PULSE ON button is pressed, the output pulse series will be generated.

In Internal PRF mode, the frequency (repetition rate) of the pulses are determined by the internal frequency generator. If externally triggered, the frequency of the pulses is determined by the frequency of the input trigger.

The delay of each of the outputs is relative to the leading edge of the T0 SYNC output.

Figure 5 Example: Pulse Count Mode

Divide By N Mode

In Divide by N Mode, OUT1 generates continuous output pulses (as in Pulse Generator Mode), and OUT2 generates an output pulse every “Nth” Output 1 pulse. The divisor is set through the Div Out1 By variable in the FREQ DIV in the CHANNEL2 menu. The X10 button will multiply this number by a factor of 10.

Page 14

MNPDG2515-2520R0.doc

© 2004 Directed Energy, Inc.

Image 21
Contents Directed ENERGY, INC Pulse of the Future Table of Contents Channel Menu Output Menu Logic Menu Configs Menu Preparation for USE List of Figures Logic & Polarity Functional DiagramSafety Warning PDG-2515 Operating Manual Quick Start Guide Menu Button Output ButtonEnter Button Up Arrow ButtonAC Power Entry Module Power LEDPW/PRF Button Out 1 and OutExample Setup Functions & Features Product OverviewDescription Outputs SpecificationsSafety Operating Safety SummaryApplications Servicing Safety Summary OperationOperating Tips Front Panel Operating Instructions Power-Up ProceduresLogic Menu Operating Modes Timing DiagramTiming Diagram Pulse Generator ModeExample 1 Pulse Generator Mode Example Pulse Count Mode Example 1 Divide by N Mode Example Burst Mode Single Shot ModeTroubleshooting Guide PDG-2520 Operating Manual Quick Start Guide This button is for navigating the PDG-2520 menus Out 1, Out 2, Out 3, Out Example Setup Channel 1 and Channel 3 operates in continuous Trigger Delay External Trigger to Sync T0 Safety Operation Output MENU1 Output MENU2 Operating Modes Pulse Generator Mode Example 2 Pulse Generator Mode with logic Divide By N Mode MNPDG2515-2520R0.doc Directed Energy, Inc Burst Mode Example Single Shot Mode Troubleshooting Guide Communications and Remote Operation RS232 OperationGpib Operation Ascii commands Command SetReply Syst Conf Load Write Save Error Set Technical Customer Service & Support Sales Customer Service & SupportContact DEI WebFactory Service & Support Product ServiceTechnical Support Warranty