Directed Electronics PDG-2515/2520 manual Operation

Page 32

PDG-2515/2520 Operating Manual

equipment when making connections in high voltage or high current circuits. Discharge high voltage capacitors after removing power.

Servicing Safety Summary

DEI strongly recommends that all repairs and adjustments be performed by factory qualified personnel. DEI will not be responsible for personal injury or damage to the pulse generator that occurs during repair by any party other than the factory. Any repairs, adjustments or modifications made by anyone other than authorized DEI personnel voids the factory warranty.

PREPARATION FOR USE

General

After unpacking, initial inspection and electrical installation procedures should be performed to assure that the unit is in good working order. If it is determined that the unit is damaged, the carrier should be notified immediately. Repair problems should be directed to the service department,

Directed Energy, Inc. (DEI),

Fort Collins, Colorado.

Telephone: (970) 493-1901

FAX: (970) 493-1903

EMAIL: deiinfo@directedenergy.com

Initial Inspection

Inspect unit for exterior mechanical damage.

Inspect power input cord and input power module for obvious signs of damage.

Electrical Installation

Standard units are shipped ready for use with a nominal 90 - 264 VAC input.

Operation

This section provides basic operating instructions for the PDG-2520 hardware.

Operating Tips

1.The four output channels have synchronized frequencies. Pulse width and pulse delay settings of one channel are dependent on the frequency of the other channels. When changing frequency be aware that both pulse width and delay are within range on both channels.

2.When using the 10X button to increase the rate at which the frequency changes, when it is first depressed the value will change by 10X, further

Page 25

MNPDG2515-2520R0.doc

© 2004 Directed Energy, Inc.

Image 32
Contents Directed ENERGY, INC Pulse of the Future Table of Contents Channel Menu Output Menu Logic Menu Configs Menu Preparation for USE Logic & Polarity Functional Diagram List of FiguresSafety Warning PDG-2515 Operating Manual Quick Start Guide Output Button Menu ButtonEnter Button Up Arrow ButtonPower LED AC Power Entry ModulePW/PRF Button Out 1 and OutExample Setup Description Functions & FeaturesProduct Overview Specifications OutputsApplications SafetyOperating Safety Summary Operating Tips Servicing Safety SummaryOperation Power-Up Procedures Front Panel Operating InstructionsLogic Menu Timing Diagram Operating ModesPulse Generator Mode Timing DiagramExample 1 Pulse Generator Mode Example Pulse Count Mode Example 1 Divide by N Mode Single Shot Mode Example Burst ModeTroubleshooting Guide PDG-2520 Operating Manual Quick Start Guide This button is for navigating the PDG-2520 menus Out 1, Out 2, Out 3, Out Example Setup Channel 1 and Channel 3 operates in continuous Trigger Delay External Trigger to Sync T0 Safety Operation Output MENU1 Output MENU2 Operating Modes Pulse Generator Mode Example 2 Pulse Generator Mode with logic Divide By N Mode MNPDG2515-2520R0.doc Directed Energy, Inc Burst Mode Example Single Shot Mode Troubleshooting Guide Gpib Operation Communications and Remote OperationRS232 Operation Reply Ascii commandsCommand Set Syst Conf Load Write Save Error Set Sales Customer Service & Support Technical Customer Service & SupportContact DEI WebTechnical Support Factory Service & SupportProduct Service Warranty