Directed Electronics PDG-2515/2520 manual Example Setup

Page 28

PDG-2515/2520 Operating Manual

The PDG-2520 accepts input voltages of 90-264VAC, 47-63Hz.

Example Setup

The default setup is 1 kHz, with zero delay and 100 us pulse on both channels. The pulse in not inverted and the pulse mode is in continuous pulse generation mode which means that pulse count is not available. By pressing the OUTPUT button on the front panel you will see these pulses on the respective outputs.

Turning the encoder with the pulses enabled and the unit will sweep the frequency on the fly, hitting the X10 button will bring you to 10 times the frequency. Pressing the down arrow twice will highlight the pulse width selection. Turn the encoder and the width will sweep. Try this with the polarity setting; it will change on the fly. Turn off the pulses.

Press MENU to continue to the settings for CHANNEL 2. Its default is the same as CHANNEL 1. Pressing the MENU button twice more will bring the user through to the last channel menu.

Hitting MENU again will bring up the first output menu, OUTPUT MENU1. This menu allows the unit to change pulse modes, disable and enable the outputs (depending on the pulse mode), and choose whether the sync is based off CHANNEL 1, 2, 3, or 4.

Hitting MENU again will bring up the second output menu, OUTPUT MENU2. This menu allows the unit to select the trigger, adjust the contrast, and select the logic applied to the output of CHANNEL 1, 2, 3, and 4.

Hitting the arrow keys allows the user to decide which settings on the current menu they would like to adjust. Press the up arrow once to scroll around to the bottom of the menu or press the down arrow 5 times. The contrast setting will be highlighted.

Turn the encoder to adjust the contrast. The contrast will adjust “on the fly” and a question mark will appear at the end of the contrast. Hit ENTER and save the contrast saving into the non-volatile memory of the unit, this setting will saved into the unit and keep this in memory even after power-down.

Page 21

MNPDG2515-2520R0.doc

© 2004 Directed Energy, Inc.

Image 28
Contents Directed ENERGY, INC Pulse of the Future Table of Contents Channel Menu Output Menu Logic Menu Configs Menu Preparation for USE Logic & Polarity Functional Diagram List of FiguresSafety Warning PDG-2515 Operating Manual Quick Start Guide Output Button Menu ButtonEnter Button Up Arrow ButtonPower LED AC Power Entry ModulePW/PRF Button Out 1 and OutExample Setup Product Overview Functions & FeaturesDescription Specifications OutputsOperating Safety Summary SafetyApplications Operation Servicing Safety SummaryOperating Tips Power-Up Procedures Front Panel Operating InstructionsLogic Menu Timing Diagram Operating ModesPulse Generator Mode Timing DiagramExample 1 Pulse Generator Mode Example Pulse Count Mode Example 1 Divide by N Mode Single Shot Mode Example Burst ModeTroubleshooting Guide PDG-2520 Operating Manual Quick Start Guide This button is for navigating the PDG-2520 menus Out 1, Out 2, Out 3, Out Example Setup Channel 1 and Channel 3 operates in continuous Trigger Delay External Trigger to Sync T0 Safety Operation Output MENU1 Output MENU2 Operating Modes Pulse Generator Mode Example 2 Pulse Generator Mode with logic Divide By N Mode MNPDG2515-2520R0.doc Directed Energy, Inc Burst Mode Example Single Shot Mode Troubleshooting Guide RS232 Operation Communications and Remote OperationGpib Operation Command Set Ascii commandsReply Syst Conf Load Write Save Error Set Sales Customer Service & Support Technical Customer Service & SupportContact DEI WebProduct Service Factory Service & SupportTechnical Support Warranty