Directed Electronics PDG-2515/2520 manual Output MENU2

Page 34

PDG-2515/2520 Operating Manual

modes will be discussed in more detail in section 9.0. Enabling and disabling a channel can also happen on the fly in all modes except Burst Mode. In Burst mode, enabling/disabling the channels is not available and Channel 1 and 2 are enabled, Channel 3 and 4 are disabled automatically. When the mode is switched from Burst mode, the enable/disable settings will return to where they were previous to Burst mode. The trigger can be set to internal or external in pulse generation and pulse count modes. Note that the unit will “lock up” until it has finished it’s pulse count in external mode so the external triggering device must give it AT LEAST as many pulses as is entered. If this does not occur, the device can be “released” by switching modes. The sync can also be run off any channel except under Burst Mode. This is especially useful in Divide By N mode and pulse count mode. Not that in Burst mode, the sync is a packet period limited by at most 95% duty cycle regardless of this setting.

OUTPUT MENU2

OUTPUT MENU2 is where the unit can change the trigger, adjust the contrast settings of the unit, and set the logic applied to the output of all Channels. The operating modes will be discussed in more detail in section

9.0.The trigger can be set to internal or external in pulse generation and pulse count modes. Note that the unit will “lock up” until it has finished it’s pulse count in external mode so the external triggering device must give it AT LEAST as many pulses as is entered. If this does not occur, the device can be “released” by switching modes. The sync can also be run off any channel when the unit is not in Burst mode (Note that in Burst mode, the sync is a packet period limited by at most 95% duty cycle regardless of this setting and outputs on Channel2 as well as the SYNC output.

The contrast setting can also be changed in this menu. If the contrast is adjusted by using the encoder knob or using the x10 button, a ‘?’ will appear at the end of the setting. This means that while the unit is powered this is the setting that the unit will retain but when powered down and powered up again the unit will revert to the last saved contrast. By depressing the ENTER button the contrast will be saved in non-volatile memory and the unit will come up under this contrast setting. The contrast is has numerous settings, and a coarse and a fine adjust. The letter is a course adjustment and the number is the fine adjust. The course adjust is manipulated with the x10 button and the fine adjust is set by the encoder knob. Logic allows the user to logically AND or OR outputs OUT1 and OUT2 with each other and OUT3 and OUT4 with each other. LOGIC1 will output on the OUT1 channel (note: the invert function will invert the channel AFTER the logic has been applied – this is shown in the LOGIC AND POLARITY FUNCTIONAL DIAGRAM below). LOGIC2 will output on the OUT2 channel, LOGIC3 will output on the OUT3 channel, and LOGIC4 will output on the OUT4 channel.

Page 27

MNPDG2515-2520R0.doc

© 2004 Directed Energy, Inc.

Image 34
Contents Directed ENERGY, INC Pulse of the Future Table of Contents Channel Menu Output Menu Logic Menu Configs Menu Preparation for USE Logic & Polarity Functional Diagram List of FiguresSafety Warning PDG-2515 Operating Manual Quick Start Guide Enter Button Output ButtonMenu Button Up Arrow ButtonPW/PRF Button Power LEDAC Power Entry Module Out 1 and OutExample Setup Product Overview Functions & FeaturesDescription Specifications OutputsOperating Safety Summary SafetyApplications Operation Servicing Safety SummaryOperating Tips Power-Up Procedures Front Panel Operating InstructionsLogic Menu Timing Diagram Operating ModesPulse Generator Mode Timing DiagramExample 1 Pulse Generator Mode Example Pulse Count Mode Example 1 Divide by N Mode Single Shot Mode Example Burst ModeTroubleshooting Guide PDG-2520 Operating Manual Quick Start Guide This button is for navigating the PDG-2520 menus Out 1, Out 2, Out 3, Out Example Setup Channel 1 and Channel 3 operates in continuous Trigger Delay External Trigger to Sync T0 Safety Operation Output MENU1 Output MENU2 Operating Modes Pulse Generator Mode Example 2 Pulse Generator Mode with logic Divide By N Mode MNPDG2515-2520R0.doc Directed Energy, Inc Burst Mode Example Single Shot Mode Troubleshooting Guide RS232 Operation Communications and Remote OperationGpib Operation Command Set Ascii commandsReply Syst Conf Load Write Save Error Set Contact DEI Sales Customer Service & SupportTechnical Customer Service & Support WebProduct Service Factory Service & SupportTechnical Support Warranty