GA-3.6H Series— PREPARATION FOR LONGTERM STORAGE
Generators Storage
For storage of the generating set for over 30 days, the following is required:
■Drain the fuel tank completely, or add
■Run the engine until the gasoline in the carburetor is completely consumed.
■Completely drain the oil from the crankcase and refill with fresh oil.
■Remove the spark plug, pour 2 or 3 cc of SAE 30 oil into the cylinder and crank slowly to distribute the oil.
■Slowly rotate the engine a few times with the starter Rope and install a new plug.
■Pull out the starter rope slowly and stop at the compression point.
■Clean all external parts of the generating set with a cloth.
■Cover the generating set and store in a clean, dry place.
PAGE 26 —