STARTING THE UNIT

Gasoline is very dangerous.

Serious injury or death may result from fire caused by gasoline contacting hot surfaces.

1.Do not fill fuel tank with engine running.

2.Do not spill fuel while refilling tank.

3.Do not mix oil with gasoline.

4.Follow all instructions and warnings in the engine

manual.

PRE-START PREPARATION

Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment.

This generator must not be operated without all factory installed heat shields in place. Failure to comply may cause the fuel tank to overheat and result in personal injury from fire.

STARTING THE ENGINE

1.Check oil level and fuel.

2.Disconnect all electrical loads from the unit.

3.Open fuel shut off valve.

4.Adjust choke as necessary.

5.Set the engine switch to the “ON" position.

6.Pull on the starter rope with fast steady pull. As the engine warms up, readjust the choke. On electric start models, turn the key switch to “START”. Release key switch after the engine starts.

Allow generator to run at no load for five minutes upon each initial start-up to permit engine and generator to stabilize.

Provide adequate ventilation for toxic exhaust gases and cooling air flow.

Do not start or run the generator in an enclosed area, even if door or windows are open.

Engines give off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide can cause nausea, fainting or death.

APPLYING LOAD

This unit has been pretested and adjusted to handle its full capacity. When starting the generator, disconnect all load. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for correct output. Readjusting will void warranty.

When applying a load, do not exceed the maximum wattage rating of the generator when using one or more receptacles. Also, do not exceed the amperage rating of any one receptacle.

SHUTTING THE GENERATOR OFF

1.Remove entire electrical load.

2.Let the engine run for two minutes without load.

3.Move the engine switch to the “OFF” position. (Turn the key switch to “OFF” on the electric start models).

4.Do not leave the generator until it has completely stopped.

5.Close the fuel shut off valve if the engine is to be put in storage or transported.

6.If a cover is used, do not install until unit has cooled.

www.powermate.com

 

10

 

Customer Hotline 1-800-445-1805

 

 

 

 

 

Image 10
Contents PMC645500 Page Stop AltoTable DES Matieres Table of ContentsIndice Safety and Operation Rules Determining Total Wattage Spark ArresterSpark Arresting Muffler Installation Operating VoltageCORD-SET Wiring Before OperationMajor Generator Features 120 V, 20 Ampere Duplex ReceptacleStarting the Engine Starting the UnitPRE-START Preparation Applying LoadInspecting the Brushes MaintenanceBREAK-IN Procedure Exciting the GeneratorService Information Service and StorageLimited Warranty Warranted Parts Voire la mort Règles D’OPÉRATION ET DE SécuritéDétermination DE LA Puissance Totale Nécessaire PARE-ÉTINCELLESSilencieux PARE-ÉTINCELLES Vérifier LA Tension Mise EN Place DE Lappareil Cable Dinstallation DE LappareilAvant DE Mettre EN Marche CarburantCaractéristiques Principales DU Groupe Electrogene Témoin de charge en pourcentage % Load Il sagit duneDémarrage DU Moteur Demarrage DE LappareilPréparatifs AU Démarrage Branchement DES AppareilsEntretien Usage ET Entreposage Service ClienteleGarantie Limitée Couverture DE Garantie DU Fabricant Reglas DE Seguridad Y DE Funcionamiento SeguridadComo Determinar EL Vataje Total ApagachispasSilenciador Apagachispas Instalacion EL Requerimiento DE VoltajeAntes DE LA Operacion Alambrado DEL Juego DE CordonesCaracteristicas Principales DEL Generador Receptáculo dúplex de 120 voltios, 20 amperesArranque DEL Motor Arranque DEL UnidadPreparacion Antes DE Arrancar Como Aplicar UNA CargaMantenimiento Servicio AL Cliente Servicio Y AlmacenamientoGarantía Limitada Cobertura DE LA Garantía DEL Fabricante Parts Drawing / Schema DES Pièces / Diagrama DE Piezas Parts List / Liste DES Pièces / Lista DE Piezas Part Description Descripción QTYCustomer Hotline Date Date Fecha Action Action Accion Airport Road Box Kearney, NE Fax