Generac 005030-0 (15kW) Duct Intake MID AL 2.5L, Duct Discharge RH AL 2.5L, Door Side HSB AL

Page 43

 

 

 

 

Section 8 - Exploded Views and Parts Lists

 

 

 

 

 

 

 

 

 

 

 

 

Liquid-cooled 15, 20 and 25 kW Generators

 

 

 

 

Enclosure — Drawing No. 0F1645-H

 

ITEM

PART NO.

QTY.

DESCRIPTION

 

1

0F0783

1

DUCT INTAKE MID AL 2.5L

 

2

0F0781

1

DUCT DISCHARGE RH AL 2.5L

 

3

0F0780

1

DUCT DISCHARGE LH AL 2.5L

 

4

0C2454

34

SCREW TH-FRM M6-1 X 16 N WA Z/JS

 

5

0F0779

1

SUPPORT RADIATOR 2.5L AL

 

6

0E0072AB

1

AI INSULATION SIDE REAR CORNER POST RH

 

7

0E0072AC

1

AI INSULATION INTAKE DUCT TOP PANEL

 

8

0E0072AD

1

AI INSULATION LH SIDE REAR CORNER POST PANEL (BOTTOM)

 

9

0E5912

2

DOOR SIDE HSB AL

 

10

0F0787

1

SUPPORT RH SIDE AL 2.5L

 

11

089961

2

FOAM STRIP 3/4" WIDE X 3/16" THK (40" LG)

 

12

0A2115

4

WASHER NYLON .257

 

13

0E0072AE

1

AI NSULATION LH SIDE REAR CORNER POST PANEL (TOP)

 

14

0F0165A

1

HINGE TYPE B W/STUDS, SOCKET

 

15

0F0165

1

HINGE TYPE B W/STUDS, PIN

 

17

022097

13

WASHER LOCK M6-1/4

 

18

022473

13

WASHER FLAT 1/4-M6 ZINC

 

19

0E7570

2

GAS SPRING

 

20

0E7571

4

BALL STUD GAS SPRING MOUNT

 

21

070015

4

NUT HEX 5/16-18 LOCK

 

22

0E7662

4

SCREW WING M6-1.00 X 25

 

23

0F0164A

1

HINGE TYPE A W/STUDS, SOCKET

 

24

0F0164

1

HINGE TYPE A W/STUDS, PIN

 

25

0D2023

3

GASKET CLIP-ON SELF GRIPPING (84" LG)

 

26

078115

8

WASHER SELF LOCKING DOME

 

27

0F2179

1

KIT SAE FOAM 2.5L QUIET SOURCE

 

28

0F0788

1

ROOF 2.5L FORD AL

 

29

0E7829B

2

AI DOOR PANEL

 

30

0D3037A

1

LATCH 1/4 TURN NONLOCKING

 

31

0C7781

2

PAWL DOOR HSB

 

32

0F0786

1

SUPPORT LH SIDE AL 2.5L

 

33

0E0072Q

2

AI INSULATION RAD SUPPORT PANEL

 

34

0D3037

1

LATCH QUARTER TURN LOCKING

 

35

0E0072Y

1

AI INSULATION SIDE BRACE PANEL RH

 

36

0E0072AF

1

AI INSULATION SIDE BRACE PANEL LH

 

37

0E0072AA

1

AI INSULATION ROOF PANEL

 

38

0F0782

1

DUCT DISCHARGE MID AL 2.5L

 

39

026850

4

WASHER SHAKEPROOF EXT 1/4 STL

 

40

0912970064

2

ASSY WIRE 14AWG 7.5 #0 GRN/YEL

 

41

0912970063

2

ASSY WIRE 14AWG 7.5 #0 GRN/YEL

 

42

049813

10

NUT HEX M6 X 1.0 G8 YEL CHR

 

43

0F0784

1

CORNER POST REAR LH SIDE AL

 

44

0F0785

1

CORNER POST REAR RH SIDE AL

 

45

0E8665

1

BRACKET STIFFENER LH FRONT

 

46

0E8837

1

DOOR BATTERY COMPARTMENT

 

47

0A3359

1

SCREW BHSC M6-1.0 X 16 SS

 

48

0E8404

1

BRACKET STIFFENER RH FRONT

* ALL ITEMS NOTATED WITH "AI" ARE COMPONENTS OF 0F2179

41

Image 43
Contents This manual should remain with the unit Introduction Authorized Service Dealer Location‹ Operation and Maintenance ‹ HOW to Obtain ServiceTable of Contents General Hazards ‹ Standards Index Electrical HazardsGenerator Transfer SwitchAutomatic Transfer Switch ATS Mode Engineered Transfer Switch Wire Start GTS ModeGenerator Fuel System ‹ 1.8.1 LOW OIL Pressure Switch‹ 1.8.2 High Coolant Temperature Switch Main Circuit BreakerLifting the Generator UnpackingFuel Consumption SpecificationsAWSF-52-C Coolant Recommendations Before InstallationEngine OIL Recommendations ‹ 2.1.2 Other Published Standards Generator LocationGenerator Mounting Support ‹ 2.1.1 Nfpa StandardsEmergency Circuit Isolation Method Basic Standby Electric SystemTotal Circuit Isolation Method Grounding the GeneratorGenerator AC Neutral Connections Connection Diagram ATS ModeConnection Diagram GTS Mode ‹ 2.11.1 Vented Batteries Battery InstallationPreparation Before START-UP Manual Transfer START-UP Control Console ComponentsBat Red Oil Red Temp Red Speed Red Crank Red Engine Governor Gain AdjustmentsAutomatic Operation Manual Retransfer ShutdownWeekly Exercise Cycle Voltage Regulator Adjustment Control Board DIP Switch SettingsIntake Manifold Procedure Exhaust Manifold ProcedureChecking Fluid Levels Cylinder Head ProcedureCooling System Overload Protection for Engine DC Electrical System‹ 4.8.1 Check Engine OIL Level ‹ 4.7.2 Battery Fluid ‹ 4.8.6 Perform Visual Inspection‹ 4.8.2 Check Battery ‹ 4.7.3 Engine Coolant‹ 4.8.13 Coolant Change Miscellaneous Maintenance‹ 4.8.11 Changing the Engine AIR Cleaner ‹ 4.9.1 Cleaning the Generator‹ 4.9.4 Battery Replacement ‹ 4.9.3 Battery MaintenancePeriodic Replacement Parts Service Maintenance Interval Information Scheduled MaintenanceLevel Maintenance Level Problem Cause Correction Troubleshooting PointsLiquid-cooled 15, 20 and 25 kW Generators Liquid-cooled 15, 20 and 25 kW Generators Electrical Data Electrical Data Electrical Data Electrical Data Electrical Data Electrical Data Electrical Data Electrical Data Page Battery Post Cover Black Support Battery TrayHold Down Battery Assembly Battery TrayTo B Duct Discharge RH AL 2.5L Assy Wire 14AWG 7.5 #0 GRN/YELDoor Battery Compartment Duct Intake MID AL 2.5LPage TOP, Control Panel Switch ROC Dpst 125V SPDSwitch ROC Dpdt ON-OFF-ON Hang TAG 2 Wire Start not ShownPage Harness Ctrl PNL 2.5L Ford AL not Shown 13 17 NUT HEX M10-1.5 G8 YEL CHR Tank Coolant RecoveryEngine 2.5L Ford STARTER, 12 VoltTo Engine Bracket Fuel Regulator Body Carburetor AssemblyCover AIR Cleaner GASKET, AIR Cleaner AdapterLocktight Rotor 390 40KW 1P Direct HSB 3.9L Chrysler Rotor 390 15KW 1P Direct HSB 2.5L FordRotor 390 20KW 1P Direct HSB 2.5L Ford Rotor 390 25KW 1P Direct HSB 2.5L FordSaddle 2 Inch Pipe Muffler OUTPipe Exhaust 2.5L Ford Muffler 2.5L FordHarn GOV 2.5L Ford Housing Governor ConnectorCover Connector Housing ASM Motor StepperRadiator 2.5L Ford HOSE, 2.5L Ford LowerBarbed STR 1/4 NPT X 3/8 ALMInstallation Diagram MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyThis Warranty Shall not Apply to the Following

005030-0 (15kW), 005031-0 (25kW) specifications

Generac has long been recognized as a leader in backup power solutions, and its 005031-0 (25kW) and 005030-0 (15kW) home standby generators exemplify the brand's commitment to reliability and performance. Designed for residential use, these generators provide peace of mind during outages, ensuring that homes remain powered even in the most challenging conditions.

One of the standout features of both models is their advanced Generac G-Force engine, which is engineered for longevity and impressive power output. The G-Force engine is built from the ground up for generator use, refined to handle the unique demands of continuous operation. This results in a highly durable system that requires little to no maintenance, making it a favored choice for homeowners looking for a reliable energy solution.

Another important characteristic is the True Power technology featured in both generators. This technology delivers clean, stable power that is safe for sensitive electronics and appliances. It ensures that devices such as computers and medical equipment operate smoothly without the risk of damage from power fluctuations. Additionally, the Generac 005031-0 and 005030-0 generators are equipped with the Quiet-Test mode, allowing them to run at lower RPMs during routine weekly self-tests. This innovation significantly reduces the noise produced during tests, making it less disruptive for residents.

Furthermore, these generators come with a user-friendly interface and a mobile link app, enabling homeowners to monitor their generator's performance remotely via a smartphone. This feature enhances convenience, allowing users to receive alerts and notifications about their generator's status, maintenance needs, and operation conditions right from their devices.

Both the 25kW and 15kW models are also designed with a robust transfer switch, which seamlessly shifts power from the grid to the generator in case of any outages. This automatic transfer feature ensures that homes maintain power without needing manual intervention, making them ideal for those who want uninterrupted electricity.

In terms of fuel source, both models operate on natural gas or propane, providing flexibility to homeowners regarding fuel availability and preferences. With excellent warranty options and Generac's reputation for quality, both the 005031-0 (25kW) and 005030-0 (15kW) generators stand as dependable choices for safeguarding homes from the unpredictability of power outages.