Generac 004451, 004582, 004451 ,004582 Part NO. QTY. Description, Control Panel Drawing No E0227

Page 33

Section 7 — Exploded Views and Parts Lists

Commercial-Industrial-Residential Portable Generator System

Control Panel – Drawing No. 0E0227

ITEM

PART NO. QTY. DESCRIPTION

1

087968

1

SWITCH, ROCKER -/0

2

090418

1

OUTLET, 12VDC SNAP

3

0D6640

1

COVER, GOVERNOR CONTROL

4

090987

6

SCREW PPHM M3-0.5 X 12

5

0D2502

1

PANEL, SHEET METAL

6

068868

2

OUTLET 30A 120V RECEPT

7

022985

2

WASHER FLAT #6

8

043182

10

WASHER LOCK M3

9

051714

6

NUT HEX M3-0.5 G8

10

075207A

4

CIRCUIT BREAKER 30A

11

075207

2

CIRCUIT BREAKER 20A

12

0D4969

1

OUTLET 50A 125/250V

13

043437

1

OUTLET 30A 125/250V

14

0D4968

1

OUTLET 20A 120V DPLX

15

0D4966

1

OUTLET 20A 120V GFCI

16

0D1004E

1

CIRCUIT BREAKER 50A 400V

 

 

 

2POLE

17

051716

8

NUT HEX M5-0.8 G8

18

022152

8

WASHER LOCK #10

19

0D5045

1

DIN RAIL 59.5mm LONG

20

067680

1

ASSEMBLY VOLTAGE REGULATOR

 

 

 

60HZ

21

0D4409

1

ELECTRONIC GOVERNOR / IDLE

 

 

 

CONTROLLER

22

052844

1

RELAY PNL 12VDC SPST 30A

23

0D4766

1

RELAY 12VDC 5A 3PDT 240V

24

0D2691

1

CONTROL PANEL BOX

25

023484L

1

BUSHING SNAP

26

0A1661

2

RIVET POP .156 X .160-.164 / #20

27

048766

1

BLOCK TERMINAL 20A 2 X 6 X

 

 

 

1100V

28

0D3550

1

BLOCK DOUBLE ROW TERMINAL 8

 

 

 

POSITION

29

049939

1

RECTIFIER MSC 12A 600V

30

070370

1

WASHER MICA .203

31

030468

1

WASHER STEP NYLON .20

ITEM

PART NO. QTY. DESCRIPTION

32

022158

1

NUT HEX #10-32

33

023897

1

WASHER FLAT #10

34

057405

1

RESISTOR 25R 5% 25W

35

022473

1

WASHER FLAT 1/4

36

022097

1

WASHER LOCK M6-1/4

37

049813

1

NUT HEX M6-1.0 G8

38

065795

2

RECTIFIER-BATTERY CHARGER

39

0D4804

2

TRANSFORMER, IDLE CURRENT

40

0C1085

4

SCREW PPHM M3-0.5 X 8

41

051715

18

NUT HEX M4-0.7 G8

42

022264

18

WASHER LOCK M4

43

048512

1

CIRCUIT BREAKER 5 X 1

44

087962

1

CIRCUIT BREAKER 10 X 1 12VDC

 

 

 

1/4"QC

45

036261

2

RIVET POP .125 X .129-.133 / #30

46

0A2769

1

LUG GRND 8 TABS

47

032300

1

HOLDER FUSE

48

028578

1

FUSE 10A X AGC10

49

055444

1

HEATSINK

50

075475

2

SCREW PPHM M4-0.7 X 10

51

049815

4

SCREW HHC M5-0.8 X 16 G8.8

52

0A2053

1

SCREW HHC M6-1.0 X 65 G8.8

53

055440

2

SCREW HHC M5-0.8 X 25 G8.8

54

045770

1

SCREW HHC M5-0.8 X 10 G8.8

55

0D5734

2

SPACER .25 X .50 X 1.5

56

074908

18

SCREW HHTT M5-0.8 X 10

57

075235

1

SCREW PPHM M5-0.8 X 30

58

080823

2

SCREW PPHM M5-0.8 X 50

59

038150

14

WASHER FLAT #8

60

0D6140

1

GASKET, PORTABLE CONTROL

 

 

 

PANEL

61

075476

2

SCREW PPHM M4-0.7 X 16

62

027565

A/R

TAPE ELEC UL PERMACEL

63

058000K

2

NUT TRIC M5-0.8

31

Image 33
Contents Ultra Source Safety Rules General Information Introduction General Hazards Important Safety InstructionsElectrical Hazards Explosion HazardsFire Hazards Accessory BOX AssemblyUnpacking Assembling the Wheel KITHandle Assembly Battery ConnectionKnow the Generator Volt AC, 30 Amp Locking Receptacle SuppliesWinter / Summer Valve See Cold Weather Operation Cord Sets and Connection Plugs 1 AC, 20 AMP, Duplex Receptacle2 120V AC, 20 AMP, Gfci Receptacle 5 12 Volt DC, 10 AMP Receptacle 120V 30AConnecting Electrical Loads HOW to USE the GeneratorDON’T Overload the Generator Grounding the GeneratorBefore Starting the Generator Wattage Reference GuideAdding Engine OIL DeviceAdding Gasoline To Start the EngineCold Weather OPERATION/ DE-ICER Automatic Idle ControlLOW OIL Pressure Shutdown System Stopping the EngineTo recharge 12 Volt batteries, proceed as follows Charging a BatteryProduct Specifications Maintenance ScheduleGenerator Specifications Engine SpecificationsGeneral Recommendations Clean Spark Arrestor Screen Service AIR CleanerTo adjust valve clearance Adjusting Valve ClearanceStorage General Long Term StorageOther Storage Tips Problem Cause Solution TroubleshootingCommercial-Industrial-Residential Portable Generator System Commercial-Industrial-Residential Portable Generator System Bearing Stator Closest Wiring Diagram Drawing No E0228Schematic Drawing No E0229 GT-990 & GT-760 Engine Page 1 Drawing No E0034 46 45 43 42QTY Description GT-990 & GT-760 Engine Page 2 Drawing No E0034 DetailaPart NO. QTY Description Generator Drawing No D4488 QTY. Description Exploded Residential No E0227 Control Panel Drawing No E0227 Part NO. QTY. DescriptionFrame, Handle & Wheel Kit Drawing No E0695 DetailRubber Tank Mount BOX 297 WHITEWATER, WI California Emission Control Warranty StatementEmission Control System Warranty Warranty Schedule Part No E0226 06/01/02

004451, 004582, 004451 ,004582 specifications

Generac is a leading manufacturer of power generation equipment, known for its robust and reliable systems. Among its vast lineup, the Generac 004451 and 004582 portable generators stand out due to their impressive features, advanced technologies, and user-friendly characteristics, making them suitable for various applications such as home backup, outdoor activities, and job sites.

The Generac 004451 model boasts a powerful 2,500-watt output, making it ideal for powering essential appliances during outages or for use in recreational settings. Its compact design enhances portability, allowing users to easily transport it wherever needed. This generator features a durable frame designed to withstand rugged environments, including a fold-down handle for convenient storage. It is equipped with a reliable 50-state compliant engine, ensuring that it meets stringent environmental regulations while delivering dependable power.

On the other hand, the Generac 004582 model is designed for users needing a bit more power, featuring a 3,200-watt maximum output. Like the 004451, it emphasizes portability and ease of use, but it also incorporates a more advanced inverter technology. This innovation ensures that the generator produces clean, stable power, making it safe for sensitive electronics like smartphones, laptops, and medical devices. The 004582's lightweight construction allows for effortless transport, while its fold-down handle and never-flat wheels enhance mobility.

Both models are engineered with user-friendly controls and features such as easy-to-read fuel gauges and a low-oil shutdown system, which prevents engine damage by automatically shutting down the generator when the oil level is too low. Additionally, these generators include multiple AC outlets, offering versatility in powering various devices simultaneously.

Safety is paramount in Generac's design philosophy, as evident in the inclusion of features such as circuit breakers to prevent overloads. Additionally, they are equipped with a robust cooling system that allows for prolonged operation without overheating.

Overall, the Generac 004451 and 004582 portable generators provide a perfect blend of power, portability, and technological advancements, making them suitable for emergency backup power, outdoor events, and job site requirements. With a strong emphasis on reliability and user convenience, Generac continues to be a trusted name in the field of power generation.