Briggs & Stratton 30228 owner manual Specifications, General Maintenance Recommendations

Page 15

MAINTENANCE

8000W Portable Generator

PowerBOSS™

 

 

 

SPECIFICATIONS

Maximum Surge Watts

12,500 Watts

Continuous Wattage Capacity

8,000 Watts

Power Factor

. . . . . . . 1.0

Rated Maximum Continuous Load Current

 

At 120 Volts

. 66.6 Amps

At 240 Volts

. 33.3 Amps

Phase

. . . 1-phase

Rated Frequency

. . 60 Hertz

Fuel Tank Capacity

8 U.S. gallons

Shipping Weight

. . . 288 lbs.

GENERAL MAINTENANCE RECOMMENDATIONS

The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. NEVER operate a damaged or defective generator.

NOTE: Should you have questions about replacing components on your Briggs & Stratton Power Products generator, please call 1-800-743-4115for assistance.

Engine Maintenance

See engine owner’s manual for instructions.

NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation.Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

Battery Maintenance

Other than float charging, described elsewhere, no maintenance is required for the battery. Keep the battery and terminals clean and dry.

IMPORTANT: Battery charging should be performed in a dry location, such as inside a garage.

CAUTION

Avoid prolonged or repeated skin contact with used motor oil.

Used motor oil has been shown to cause skin cancer in certain laboratory animals.

Thoroughly wash exposed areas with soap and water.

KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.

Generator Cleaning

• Use a damp cloth to wipe exterior surfaces clean.

CAUTION

Improper treatment of generator can damage it and shorten its life.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

Use a soft bristle brush to loosen caked on dirt or oil.

Use a vacuum cleaner to pick up loose dirt.

Use low pressure air (not to exceed 25 psi) to blow away dirt. Inspect cooling air slots and opening on generator.These openings must be kept clean and unobstructed.

15

Image 15
Contents Model / Modelo 030228 8000W Table of Contents Safety RulesEquipment Description When Transporting or Repairing Equipment When Adding or Draining FuelWhen Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Assembly Install Wheel KitRemove Generator From Carton Add Fuel Check Battery / Attach Negative Battery WireWhen Adding Fuel Before Starting the EngineGenerator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundJump Start Procedure Operating GeneratorStarting the Engine Connecting Electrical Loads How to Use the Battery ChargerStopping the Engine Permanent Cold Weather Shelter Cold Weather OperationReceptacles Volt AC, 50 Amp Receptacle120/240 Volt AC, 30 Amp, Locking Receptacle Volt AC, 20 Amp, Duplex Receptacle Volt AC, 30 Amp Locking ReceptaclePower Management DON’T Overload GeneratorCapacity General Maintenance Recommendations SpecificationsStorage Generator StorageEngine Storage Other Storage Tips Problem Cause Correction TroubleshootingPowerBOSS Limited Warranty Advertencia Conserve Estas Instrucciones Tabla DE ContenidosDescripción DEL Equipo Reglas DE SeguridadCuando Transporte O Repare EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoPrecaución Cuando Ajuste O Haga Reparaciones a SU GeneradorCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Montaje Para Retirar El Generador De La CajaInstale el Juego de Ruedas Para instalar Antes DE Darle Arranque AL MotorAgregar Aceite al Motor Agregue CombustibleUbicación del Generador USO DEL GeneradorTierra del Sistema Conexión al Sistema Eléctrico de un EdificioEncienda el Motor Operando EL Generador PrecauciónNo Sobrecargue GENERADOR. Vea No Sobrecargue Generador Procedimiento de Arranque en PuenteConexion De Cargas Electricas Parado Del MotorCómo al Uso el Corcel de Batería Operación Durante UN Clima FríoVoltios AC, 50 Amperios Receptáculo Receptáculos Precaución120/240 Voltios AC, 30 Amperios, Receptáculo de Seguridad Volt AC, 20 Amperios, Receptáculos DoblesTomacorrientes de 120 Voltios AC, 30 Amperios Ejemplo No Sobrecargue GeneradorCapacidad Control de la EnergíaRecomendaciones Generales DE Mantenimiento EspecificacionesOtras Sugerencias Para el Almacenando AlmacenamientoAlmacenando el Generador Almacenando el MotorDiagnositicos DE Averías Garantía Limitada

30228 specifications

The Briggs & Stratton 30228 is a high-performance generator designed for a variety of residential and commercial applications. Known for its reliability and durability, this portable generator is an excellent choice for anyone in need of backup power during outages or for outdoor activities that require electricity.

One of the standout features of the Briggs & Stratton 30228 is its powerful engine. Equipped with a 479cc OHV (Overhead Valve) engine, it delivers a robust output of 7,500 running watts and up to 9,375 starting watts. This ensures that users can run multiple appliances simultaneously, making it suitable for powering everything from refrigerators and air conditioners to power tools and more.

The generator's design incorporates advanced technologies aimed at maximizing efficiency and usability. One notable feature is its SureStart technology, which ensures easy starting even in low temperatures or after prolonged storage. The automatic idle control feature helps reduce fuel consumption by adjusting the engine speed to match the electrical load, ultimately saving on operational costs and extending run time.

Additionally, the Briggs & Stratton 30228 is built with a heavy-duty steel frame to protect the engine and components from rough handling, ensuring long-lasting performance. Its 7.5-gallon fuel tank provides extended run times, capable of delivering up to 9 hours of continuous power at a 50% load.

The generator features multiple outlets, including four 120V AC outlets, one 120/240V twist-lock outlet for heavy-duty applications, and a circuit breaker for added safety protection. Users will appreciate the ease of transport thanks to its built-in foldable handles and rugged wheels, enabling smooth mobility across various terrains.

Overall, the Briggs & Stratton 30228 combines powerful performance with advanced features and durability, making it an ideal solution for those looking for a reliable power source for emergencies or outdoor activities. Its user-friendly design and efficiency make it a top contender in the portable generator market, appealing to both casual users and professionals alike. Whether for home use or job site applications, this generator proves to be a dependable companion, ensuring that power is just a pull start away.