Briggs & Stratton 30219 manual Before Starting Engine, Add Engine Oil, Add Fuel, Type of Fuel

Page 7

ASSEMBLY

BEFORE STARTING THE

NOTE: Fuel with up to 10% ethanol (gasohol) or up to 15% MTBE (methyl tertiary butyl ether), is acceptable.

ENGINE

Add Engine Oil

CAUTION! Any attempt to crank or start the engine before it has been properly serviced with the recommended oil may result in an engine failure.

1.Place generator on a flat, level surface.

2.Clean area around oil fill and remove yellow oil fill cap.

NOTE: See the section “Oil” on page 14 to review oil recommendations.Verify provided oil bottle is correct vicosity for current ambient temperature.

3.Using oil funnel (optional), slowly pour contents of provided oil bottle into oil fill opening.

4.Replace oil fill cap and fully tighten.

Add Fuel

All fuel is not the same. If a starting or performance problem is encountered immediately after new fuel has been used, try another service station or change brands.

NOTE: This engine is certified to operate on gasoline.

Exhaust Emissions Control System: EM (Engine Modifications).

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

Wait for spilled fuel to evaporate before starting engine.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

Type of Fuel

1.Always use clean, fresh, UNLEADED gasoline with a minimum of 87 octane/87 AKI (91 RON) with equipment. DO NOT mix oil with fuel. DO NOT modify the engine fuel system or carburetor to run on alternative fuels.

IMPORTANT: Use of any fuel other than those approved above will void warranty. Some areas require that fuel pumps be marked if the fuel contains alcohols or ethers. If you are not sure if your fuel contains alcohol or ethers that are different than those approved above, then check with the service station operator.

2.Clean area around fuel fill cap, remove cap.

3.Slowly add unleaded gasoline to fuel tank. Be careful not to overfill. Allow about 1.5" of tank space for fuel expansion, as shown in Figure 2.

Figure 2 - Fuel Expansion

AirSpace

Tank

Fuel

1.5”

 

4.Install fuel cap and let any spilled fuel evaporate before starting engine.

To avoid engine problems, the fuel system should be treated with a fuel preserver or emptied before storage of 30 days or longer.To protect the fuel system from gum formation, use Briggs & Stratton FRESH START™ fuel stabilizer plus, or FRESH START™ continuous fuel preserver (concentrated liquid cartridge), or FRESH START™ preservative & stabilizer (granular). If fuel preserver is not used, drain the fuel tank, start the engine and let it run until the fuel lines and carburetor are empty. Use fresh fuel next season. See “Storage” on page 17 for additional information.

NEVER use engine or carburetor cleaner products in the fuel tank as permanent damage may occur.

High-altitude use

Operation at high altitudes (over 5,000 feet), may require a high-altitude carburetor jet kit to improve performance and decrease fuel consumption. See your local authorized Briggs & Stratton dealer for more information.

7

Image 7
Contents Operator’s Manual Manual del Operario Starting WattsCall Generator Helpline Llame Línea Directa del Generador Safety Rules Table of ContentsEquipment Description When Transporting or Repairing Equipment When Adding or Draining FuelWhen Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Unpacking the Generator AssemblyInstall Wheel Kit Refer to and install the wheel kit as followsType of Fuel Before Starting EngineAdd Engine Oil Add FuelGenerator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundStarting the Engine Operating GeneratorStopping the Engine Connecting Electrical LoadsReceptacles Generator Adapter Cord SETExample Power ManagementDont Overload Generator CapacityEngine Specifications Product SpecificationsGenerator Specifications Power RatingsGenerator Cleaning Generator MaintenanceGeneral Recommendations Service Air Cleaner Engine MaintenanceOil Changing Engine Oil Clean/Replace Spark PlugClean Spark Arrester Screen To service the air cleaner, follow these stepsClean and inspect the spark arrester as follows Carburetor AdjustmentAir Cooling System Generator StorageLong Term Storage Instructions Protect Fuel SystemTroubleshooting Page Owner’s Warranty Responsibilities Emissions Control System WarrantyPage Page Limited Warranty Advertencia Tabla DE ContenidosDescripción DEL Equipo Reglas DE SeguridadCuando Transporte O Repare EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Tapa del Depósito del Aceite Llene el motor con aceite Conozca SU GeneradorTomacorriente Dobles de 120 Voltios AC, 20 Amp Desembalaje del Generador MontajeInstale el Juego de Ruedas Cuando Añada Combustible Antes DE Darle Arranque AL MotorAgregar Aceite al Motor Agregue CombustibleUbicación del Generador USO DEL GeneradorTierra del Sistema Conexión al Sistema Eléctrico de un EdificioEncienda el Motor Operando EL GeneradorParado Del Motor Juego DE Cables DEL Adaptador DEL GeneradorReceptáculos Precaución Conexion De Cargas ElectricasEjemplo No Sobrecargue GeneradorCapacidad Control de la EnergíaPotencia Nominal Información Técnica Sobre EL MotorEspecificaciones DEL Producto Especificaciones del GeneradorLimpieza del Generador Recomendaciones GeneralesMantenimiento DEL GeneradorAceite Mantenimiento DEL Motor AdvertenciaServicio del Depurador de Aire Cambio de Aceite del Motor Limpie/Reemplace la BujíaLimpie la Pantalla Apagachispas Ajuste del Carburador Sistema de Refrigeración de AireLimpie e inspeccione el apagachispas de la siguiente manera Generador AlmacenamientoAlmacenamiento Para Periodos Prolongados Proteja el Sistema de CombustibleDiagnositicos DE Averías Problemo Causa AccionNotas Garantía DEL Sistema DE Control DE Emisiones = 250 horas, B = 500 horas y a = 1000 horas Uso comercial Uso del consumidor

30219 specifications

The Briggs & Stratton 30219 is a highly regarded gasoline-powered generator that epitomizes reliability and performance for both residential and small commercial applications. This model is particularly popular among homeowners who require a dependable source of backup power during outages or those who want to power outdoor events and tools.

One of the standout features of the Briggs & Stratton 30219 is its impressive power output. With a 3,200 running watts and a peak output of 3,750 watts, it is capable of powering essential home appliances, such as refrigerators, heating systems, and quickly rechargeable devices. This capability makes it an excellent choice for emergency power solutions, ensuring that users can maintain comfort and functionality during unexpected power interruptions.

At the heart of the 30219 generator is a robust engine designed for longevity and efficiency. The 162cc OHV (Overhead Valve) engine provides a strong performance while maintaining fuel efficiency, allowing users to maximize their runtime. This generator is engineered with a 1.5-gallon fuel tank, providing up to 8 hours of continuous operation at 50% load, which is essential when you need consistent power without frequent refueling.

In terms of portability, the Briggs & Stratton 30219 incorporates a compact and lightweight design. It is equipped with a sturdy handle and wheels, making it easy to transport from one location to another. This is particularly beneficial for users who may need to move the generator for outdoor activities, construction sites, or emergency situations.

Safety is also a vital concern for users during operation. The Briggs & Stratton 30219 is equipped with a built-in low-oil shutdown feature, which automatically turns off the engine when oil levels become too low. This helps to prevent engine damage and extends the life of the generator. Additionally, it includes multiple outlets, providing versatility for connecting various devices while ensuring that users can power multiple items simultaneously.

Overall, the Briggs & Stratton 30219 generator is a powerful, efficient, and portable solution suitable for a variety of power needs. With its durable construction, reliable performance, and user-friendly features, it continues to earn a reputation as one of the best choices on the market for those seeking dependable backup power. Whether experiencing an outage or powering outdoor activities, the 30219 generator stands ready to perform.