WARNING

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide can cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.

DO NOT operate generator inside any building or enclosure (even if doors or windows are open), including the generator compartment of a recreational vehicle (RV).

WARNING

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain or wet weather.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

WARNING

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING OR DRAINING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill or drain fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

Wait for spilled fuel to evaporate before starting engine.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

WHEN STARTING EQUIPMENT

Ensure spark plug, muffler, fuel cap and air cleaner are in place.

DO NOT crank engine with spark plug removed.

WHEN OPERATING EQUIPMENT

DO NOT tip engine or equipment at angle which causes fuel to spill.

This generator is not for use in mobile equipment or marine applications.

WHEN TRANSPORTING OR REPAIRING EQUIPMENT

Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.

Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

WARNING

This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.

Failure to use the appropriate U. S. Coast Guard approved generator could result in death or serious injury and/or property damage.

3

Image 3
Contents Starting Watts Operator’s Manual Manual del OperarioCall Generator Helpline Llame Línea Directa del Generador Table of Contents Safety RulesEquipment Description When Transporting or Repairing Equipment When Adding or Draining FuelWhen Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Unpacking the Generator AssemblyInstall Wheel Kit Refer to and install the wheel kit as followsType of Fuel Before Starting the EngineAdd Engine Oil Add FuelGenerator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundStarting the Engine Operating GeneratorVolt AC, 20 Amp, Duplex Receptacles Connecting Electrical LoadsReceptacles Stopping the EngineExample Power ManagementDont Overload Generator CapacityEngine Specifications Product SpecificationsGenerator Specifications Power RatingsGenerator Maintenance Generator CleaningGeneral Recommendations Engine Maintenance Servicing Air CleanerOil Servicing Spark Arrester To service the air cleaner, follow these stepsChanging Engine Oil Servicing Spark PlugClean Cooling System Carburetor AdjustmentClean and inspect the spark arrester as follows Generator StorageLong Term Storage Instructions Protect Fuel SystemTroubleshooting Page Owner’s Warranty Responsibilities Emissions Control System WarrantyPage Page Limited Warranty Advertencia Tabla DE ContenidosDescripción DEL Equipo Reglas DE SeguridadCuando Transporte O Repare EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoPrecaución Cuando Ajuste O Haga Reparaciones a SU GeneradorCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Montaje Desembalaje del GeneradorInstale el Juego de Ruedas Cuando Añada Combustible Antes DE Darle Arranque AL MotorAgregar Aceite al Motor Agregue CombustibleUbicación del Generador USO DEL GeneradorTierra del Sistema Conexión al Sistema Eléctrico de un EdificioEncienda el Motor Operando EL GeneradorVolt AC, 20 Amperios, Receptáculos Dobles Receptáculos PrecauciónConexion De Cargas Electricas Parado Del MotorEjemplo No Sobrecargue GeneradorCapacidad Control de la EnergíaPotencia Nominal Información Técnica Sobre EL MotorEspecificaciones DEL Producto Especificaciones del GeneradorLimpieza del Generador Recomendaciones GeneralesMantenimiento DEL GeneradorMantenimiento DEL Motor Advertencia AceiteServicio del Depurador de Aire Para revisar el filtro de aire, siga estos pasos Cambio de Aceite del MotorLimpie/Reemplace la Bujía Limpie la Pantalla ApagachispasSistema de Refrigeración de Aire Ajuste del CarburadorLimpie e inspeccione el apagachispas de la siguiente manera Generador AlmacenamientoAlmacenamiento Para Periodos Prolongados Proteja el Sistema de CombustibleDiagnositicos DE Averías Problemo Causa AccionNotas Garantía DEL Sistema DE Control DE Emisiones = 250 horas, B = 500 horas y a = 1000 horas Uso comercial Uso del consumidor

030319, 030320 specifications

Briggs & Stratton has been a trusted name in the power equipment industry for over a century, and their 030320 and 030319 models are perfect examples of their commitment to quality and innovation. These engines are designed to power a variety of outdoor equipment, including lawn mowers, generators, and pressure washers, making them a versatile choice for homeowners and professionals alike.

One of the main features of the Briggs & Stratton 030320 and 030319 engines is their impressive power output. The 030320 model boasts a robust 550cc displacement, while the 030319 offers a slightly lower 450cc. This power enables these engines to tackle demanding tasks with ease, ensuring that users can complete their projects efficiently and effectively.

Both models are equipped with advanced technologies that enhance performance and reliability. The ReadyStart system allows for effortless starting without the need to prime or choke the engine, significantly reducing the time spent preparing the equipment for use. Additionally, the engines feature a durable overhead valve (OHV) design, which promotes better fuel efficiency and reduced emissions compared to traditional side-valve engines.

Another key characteristic of the Briggs & Stratton 030320 and 030319 engines is their robust construction. They are built with high-quality materials, which provide durability and longevity, making them suitable for heavy-duty applications. The engines also feature a steel crankshaft that withstands high-stress conditions and a cast iron sleeve for improved wear resistance.

Maintenance is made easy with these engines, thanks to their accessible oil drain and air filter design. Users can quickly change the oil and replace the air filter, ensuring that the engine functions at peak performance over time. This focus on user-friendly maintenance makes the 030320 and 030319 models ideal for individuals who want reliable performance without the hassle of complicated upkeep.

Safety is also a priority in the design of these engines. They come equipped with features such as a low-oil shutdown system that automatically turns off the engine when oil levels drop too low, preventing potential damage. This added layer of protection ensures that users can operate their equipment with peace of mind.

In summary, the Briggs & Stratton 030320 and 030319 engines combine power, efficiency, durability, and user-friendly features. Whether you are a homeowner tackling seasonal yard work or a professional in need of reliable equipment, these engines deliver exceptional performance and reliability, solidifying Briggs & Stratton’s reputation as a leader in the industry.