Briggs & Stratton 30348 manual Troubleshooting

Page 20

Troubleshooting

Problem

Cause

Correction

 

1.

One of the circuit breakers is open.

1.

Reset circuit breaker.

Engine is running, but no AC

2.

Fault in generator.

2.

Contact authorized service facility.

3.

Poor connection or defective cord set.

3.

Check and repair.

output is available.

4.

Connected device is bad.

4.

Connect another device that is in good

 

 

 

 

 

condition.

 

 

 

 

 

 

1.

Short circuit in a connected load.

1.

Disconnect shorted electrical load.

Engine runs good at no-load but

2.

Engine speed is too slow.

2.

Contact authorized service facility.

“bogs down” when loads are

3.

Generator is overloaded.

3.

See Don’t Overload Generator in

connected.

 

 

 

Operation section.

 

4.

Shorted generator circuit.

4.

Contact authorized service facility.

 

 

 

 

 

 

1.

Rocker switch set to “Off”.

1.

Set switch to “On”.

 

2.

Fuel Valve is in “Off” position.

2.

Turn fuel valve to “Open” position.

 

3.

Dirty air cleaner.

3.

Clean or replace air cleaner.

 

4.

Out of fuel.

4.

Fill fuel tank.

 

5.

Stale fuel.

5.

Drain fuel tank and carburetor; fill with

 

 

 

 

fresh fuel.

Engine will not start; or starts

6.

Spark plug wire not connected to spark

6.

Connect wire to spark plug.

 

plug.

 

 

and runs rough.

 

 

 

7.

Bad spark plug.

7.

Replace spark plug.

 

 

8.

Water in fuel.

8.

Drain gas tank and carburetor; fill with

 

 

 

 

fresh fuel.

 

9.

Flooded.

9.

Wait 5 minutes and re-crank engine.

 

10.

Excessively rich fuel mixture.

10.

Contact authorized service facility.

 

11.

Intake valve stuck open or closed.

11.

Contact authorized service facility.

 

12.

Engine has lost compression.

12.

Contact authorized service facility.

 

 

 

Engine shuts down when

Out of fuel.

Fill fuel tank.

running.

 

 

 

 

 

 

 

 

 

 

1.

Load is too high.

1.

See Don’t Overload Generator in

Engine lacks power.

 

 

 

Operation section.

 

2.

Dirty air filter.

2.

Replace air filter.

 

 

 

Engine “hunts” or falters.

Carburetor is running too rich or too lean.

Contact authorized service facility.

 

 

 

 

 

18

BRIGGSandSTRATTON.COM

Image 20
Contents Operator’s Manual Where to Find Us GeneratorEngine Date PurchasedTable of Contents Operator Safety Safety RulesSafety alert symbol is used with a signal word Equipment DescriptionEngine exhaust from this product contains Broken bones, fractures, bruises, or sprains could resultUnintentional sparking can result in fire or electric shock When Testing for Engine SparkContact with muffler area can result in serious burns Assembly Install Wheel KitShipment Contents Unpack GeneratorAdd Engine Oil Add FuelFuel must meet these requirements High AltitudeConnecting to a Building’s Electrical System System GroundGenerator Location Special RequirementsFeatures and Controls Items Not ShownCord Sets and Receptacles Nema L14-20120/240 Volt AC, 20 Amp, Locking Receptacle Volt AC, 20 Amp, Duplex ReceptaclesOperation Starting the EngineMove fuel valve to Off position Connecting Electrical LoadsStopping the Engine Don’t Overload Generator Wattage Reference GuideGenerator Maintenance MaintenanceMaintenance Schedule Engine Maintenance OilService Air Cleaner Service Spark PlugInstall spark plug and tighten firmly Service Spark ArresterCarburetor Adjustment Air Cooling SystemStorage Troubleshooting Warranties Emissions Control System WarrantyOwner’s Warranty Responsibilities Claims and Coverage Exclusions MaintenanceEmission Information Limited Warranty 800 Product SpecificationsCommon Service Parts Manual del Operario Dónde encontrarnos GeneradorMotor Fecha de compraResolución de problemas Garantías Seguridad de OperarioMontaje Controles y característicasSeguridad de operario Descripción del equipoReglas de seguridad Símbolos de peligro y sus significadosCuando Anada Combustible O Vacíe EL Depósito Cuando Ponga EN Funcionamiento EL EquipoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Ajuste O Haga Reparaciones a SU Máquina Generador Cuando Pruebe LA Bujía DEL MotorMontaje Desembalaje del generadorInstale el juego de ruedas Contenido de la cajaAgregar aceite al motor Vuelva a colocar el tapón y apriételo firmementeEvite el daño del generador Gran altitudTierra del sistema Conexión al sistema eléctrico de un edificioUbicación del generador Requisitos especialesControles y características Amperios, monofásica de 60 HzJuegos de cordones y enchufes conectores 120/240 Voltios AC, 20 Amperios, Receptáculo de SeguridadTierra Verde Tomas eléctricas dobles de 120 V CA y 20 aOperando Encienda el motorConexión de cargas eléctricas Parada del motorEl motor podría petardear, incendiarse o dañarse Gire la válvula de combustible blanca hasta la posición OffNo sobrecargar el generador CapacidadEjemplo Control de la energíaMantenimiento del Generador MantenimientoPlan de mantenimiento Mantenimiento del Motor Aceite Recomendaciones sobre el aceiteComprobación del Nivel de Aceite Adición de Aceite del MotorServicio del depurador de aire Limpia BServicio del bujía Limpie la Pantalla ApagachispasAjuste del Carburador Limpie e inspeccione el apagachispas de la siguiente maneraSistema de refrigeración de aire Almacenamiento Resolución de problemas Problemo Causa AccionResponsabilidades de la garantía del propietario GarantíasGarantía del sistema de control de emisiones Información sobre emisiones Garantía Limitada Especificaciones del producto Servicio común despide