Section 9 - Exploded Views and Parts

 

 

 

Bryant Liquid-cooled 15 kW Generators

 

 

 

Enclosure — Drawing No. 0F4490

ITEM

PART NO.

QTY.

DESCRIPTION

1

0D8666

1

ROOF ACSTC&STND CMPRTMNT 1.5L

2

0D8664C

1

DUCT CENTER 1.5L

3

0D8657

1

SUPPORT RADIATOR 1.5L MITSU

4

0D8660

2

BRACE SIDE 1.5L MITSU

5

0A7568

2

DOORWELDMENT 1.5EPS

6

0D8659

1

CORNER POST REAR RH SIDE 1.5L

7

0D8662

1

DOOR REAR COMPARTMENT 1.5L

8

0D8661

1

BRACE REAR 1.5L MITSU

9

0D8658

1

CORNER POST REAR LH SIDE 1.5L

10

067042

2

LATCH & CAM

11

0C2454

40

SCREW TH-FRM M6-1 X 16 N WA Z/JS

12

033530

3

SCREW PHM #10-32 X 5/8 ZINC

13

051716

3

NUT HEX M5-0.8 G8 YEL CHR

14

022152

3

WASHER LOCK #10

15

0912970064

3

ASSEMBLY BASE-DOOR GROUND WIRE

16

023762

3

WASHER SHAKEPROOF EXT #10 STL

17

0912970063

3

GRD WIRE ASS'Y 99HSB

18

022264

6

WASHER LOCK #8-M4

19

067035

6

SCREW PPHM #8-32 X 5/16

20

022127

1

NUT HEX 1/4-20 STEEL

21

0F4487A

1

ASSEMBLY COVER ACCESS

22

022473

1

WASHER FLAT 1/4 ZINC

23

022097

1

WASHER LOCK M6-1/4

24

0D2023

3

GASKET CLIP-ON SELF GRIPPING

25

0F3390

1

LATCH AND CAM

26

037337

6

NUT HEX JAM 3/8-24 SS

27

0D2023

21

GASKET CLIP-ON SELF GRIPPING

28

0D8664A

1

DUCT LH SIDE 1.5L

29

0D8664B

1

DUCT RH SIDE 1.5L

Bryant 31

Image 33
Contents Liquid-cooled, Prepackaged Standby Generators ‹ HOW to Obtain Service ‹ Operation and MaintenanceIntroduction Your Bryant Dealer isIntroduction IFC Safety Rules General Hazards ‹ Standards Index Fire HazardsGenerator Transfer SwitchAutomatic System Operation Generator AC Connection Systems‹ 1.7.2 High Coolant Temperature Switch ‹ 1.7.1 LOW OIL Pressure Switch‹ 1.7.3 LOW Coolant Level Switch Generator Fuel SystemSpecifications UnpackingLifting the Generator Torque Specifications Reconfiguring the Fuel System‹ 1.10.2 Engine Specifications Fuel ConsumptionEngine OIL Recommendations Before InstallationCoolant Recommendations ‹ 2.1.1 Nfpa StandardsBasic Standby Electric System Generator Mounting SupportGenerator Location ‹ 2.1.2 Other Published StandardsEmergency Circuit Isolation Method Transfer Switch Signal ConnectionsTotal Circuit Isolation Method Generator AC Neutral ConnectionsPreparation Before START-UP Battery Installation‹ 2.10.1 Vented Batteries ‹ 2.11.1 Prior to Initial START-UPControl Console Components ‹ 3.1.5 SET Exercise Time Switch ‹ 3.1.2 Fault Indicator LampManual Transfer START-UP Automatic Operation Weekly Exercise CycleOverload Protection for Engine DC Electrical System Cooling SystemChecking Fluid Levels ‹ 4.5.2 Check Battery ‹ 4.4.2 Battery Fluid ‹ 4.5.7 Inspect Exhaust System‹ 4.4.3 Engine Coolant ‹ 4.5.1 Check Engine OIL Level‹ 4.5.11 Changing the Engine AIR Cleaner Miscellaneous Maintenance‹ 4.6.1 Cleaning the Generator ‹ 4.5.12 Spark Plugs‹ 4.6.2 Battery ‹ 4.6.3 Battery Maintenance‹ 4.6.4 Battery Replacement Service Maintenance Interval Information Scheduled MaintenanceLevel Maintenance Level Problem Cause Correction Troubleshooting PointsBryant Liquid-cooled 15 kW Generators Installation Diagram Electrical Data Customer Connection DC-VR To Control Panel Terminal Strip Connector Interface Assembly Housing Governor ConnectorCover Connector Housing ASM Motor StepperWasher Shakeproof EXT 5/16 STL Base Mounting 1.5L Stnrd & AcstcDampener Vibration Washer Flat 5/16 ZincPanel for Access GRD Wire Assy 99HSB Assembly BASE-DOOR Ground WireAssembly Cover Access Roof ACSTC&STND Cmprtmnt 1.5LATO Wire Assembly Switch ROC Dpdt ON-OFF-ONPanel Back & Bottom Screw Hhtt M5-0.8 X 12 BPWaterpump Hardware ARM Adjust Alternator Switch OIL PressureGround Wire Starter ENGINE-1.5L14 21 Radiator 1.5L Tank Coolant RecoveryVenturi 1.5L Modine Guard FAN 1.5L ModineVapor Gasket AIR Cleaner Adapter Cover AIR CleanerWeldment Mounting Base Flange Fuel InletOTH Blowgousin re Assy Rotor 10KW Housing BlowerAssy Rotor 15KW Assy Rotor 20KWBOOT, Battery Cable ASSY,WIRE#16 REDBRACKET, Battery Hold Down Battery Post Cover RED+Nipple TOE 1.5NPTX5.5 BLK Iron Manifold Exhaust 1.5LSaddle 2 Inch PIPE,EXHAUST 1.5L STNDRD&ACSTCYour Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule

ASPAS1BBL015 specifications

The Bryant ASPAS1BBL015 is a cutting-edge air conditioning unit designed to provide efficient cooling solutions for residential and commercial spaces. As part of Bryant's renowned lineup of HVAC equipment, the ASPAS1BBL015 combines advanced technology with user-friendly features to ensure optimal comfort in any environment.

One of the standout features of the ASPAS1BBL015 is its innovative inverter technology. This technology allows the unit to adjust its cooling output according to the ambient temperature, which enhances energy efficiency and reduces electricity costs. Unlike traditional air conditioning units that operate at a fixed speed, the inverter system ensures that the compressor runs at variable speeds, providing a more stable and comfortable temperature without excessive energy consumption.

Another significant characteristic of the ASPAS1BBL015 is its whisper-quiet operation. Designed with noise-reduction technology, this air conditioning model operates at low decibel levels, making it ideal for environments where silence is paramount, such as bedrooms or office spaces. Users can enjoy a serene atmosphere while still benefiting from effective cooling performance.

The Bryant ASPAS1BBL015 also incorporates a multipurpose filtration system. This advanced filtration mechanism not only cools the air but also filters out dust, allergens, and other airborne pollutants, ensuring that the air circulating in the living space is clean and healthy. This is a crucial feature for those who suffer from allergies or respiratory issues, as it promotes a healthier indoor environment.

Moreover, the unit is built with durability in mind. Constructed using high-quality materials, the ASPAS1BBL015 is designed to withstand various weather conditions and is resistant to corrosion, ensuring that it continues to function efficiently over many years. The compact and sleek design of the unit allows for easy installation and integration into existing setups without being obtrusive.

In terms of control options, the ASPAS1BBL015 is compatible with smart home systems, allowing users to manage temperature settings remotely via mobile apps. This feature adds an extra level of convenience, enabling users to fine-tune their comfort levels from anywhere.

In conclusion, the Bryant ASPAS1BBL015 air conditioning unit is a powerful and efficient solution for those seeking reliable cooling technology. With its inverter technology, whisper-quiet operation, advanced filtration, durability, and smart control features, it stands out as an exceptional choice for anyone looking to enhance their indoor climate experience. Whether for residential or commercial use, the ASPAS1BBL015 delivers outstanding performance and comfort.