distributor of the sprayer only when the cylinders are being used. We recommend having qualified personnel do any adjustments.

5.2AIR-ASSISTED BOOMS

These are booms that use air to make the treatment more effective and decrease wind drift.

They are equipped with a fan (normally hydraulic) and an AIR- SLEEVE that transports the airflow along the entire length of the boom.

They come with their own use and maintenance handbook, en- closed with the machine.

Air-assisted booms

5.3SELF-LEVELING DEVICES

The self-levelling device keeps the boom parallel to the ground to be treated. It works thanks to the effect of gravity in all the models (except TDL). The oscillation can be blocked mechanically (TDE-TDM) or hydraulically (TDI). The Work boom has a self-levelling device with an automatic block based on cables and springs.

The self-levelling device only works on flat ground, for hilly terrain we recommend the version with trim corrector (TDI 2P) or hydraulic LEVELING (TDL), which lets the operator position the boom with an inclination that is suitable for the ground.

To use, check:

a)that the boom has been mounted in the centre, the weight of the boom must be supported equally on the two halves. To check this, free the self-levelling device from the mechanical (or hydraulic) block and by moving the boom make sure it automatically adjusts its position to be parallel to the ground.

b)in the models that have an adjustable connecting rod, by adjusting the same, it is possible to obtain small variations in trim that can be useful on slightly uneven terrain.

c)in the hydraulic versions it is possible to fit a hydraulic cylinder (TDI 2P) instead of the connecting rod that is adjusted by hand.

d)to complete the self-levelling device we recommend the dragging jet-saver protections

e)keep the sliding parts well greased.

5.3.1 VARIABLE GEOMETRY

Some models of hydraulic boom are equipped with a variable geometry system of the side arms for independent inclination, this system can be used as an alternative to the trim correction or combined with the same.

The angle of the arms is controlled by the operator with electrohydraulic controls.

Self-levelling

Self-levelling blocking system

Variable geometry

unigreen 21

Image 21
Contents 10/2007 USE and Maintenance ManualSummary Hand Lances Hose Reel Maintenance Composition of the Manual GuaranteeImproper use Product Responsibility Unigreen spa is not responsible ifKey to the symbols Intended USE Using Chemical ProductsProhibited USE RecommendationsCharacteristics and Specifications Machines Designed to be Used only with Clean WaterWeather Conditions Driving on the RoadNoise Level of the Machine Standards of ReferenceUSER’S Instructions Description of the Machine Hand Washing Tanks Work StationsPreliminary Checks Transporting and Moving the MachineTowed Sprayers Parking Tractor CouplingStandard Version Elevator Coupling Wheel Spacing Adjustment Hook Version HomologatedParking Foot Cardan Shaft Hydraulic Connection to the DistributorsSuction Filter PumpComponents of the Pressure Regulator Pressure RegulatorControl box for Ergo and Remo electrical regulators General InstructionsSpraying Computer Optional Mixing Filling the TankManual Premixing Premixer on Cover OptionalPremixer on Hopper with TIN Washer Optional TOP-Mix S41HOW to USE the LP83 Incorporator Washing the Sprayer Circuit Washer and Tank WasherWashing with Full Tank Optional Hydraulic Herbicide Booms Horizontal Booms for Herbacious CultivationsExceed a height of 4 meters Indipendent Hydraulic PlantAIR-ASSISTED Booms SELF-LEVELING DevicesVariable Geometry Distrubution with Herbicide Boom LiftingDescription of Type of Jets Description of Type of Nozzles=600xQ Useful InformationMarker Hand LancesHose Reel Programmed Maintenance TAB. N MaintenanceRoutine Maintenance Extraordinary MaintenanceDemolition and Disposal Putting Back Into Service After Winter LayupMaterials for Demolition Electrical and Electronic Apparatus Waste EeawUnigreen Arancio Orange Verde Green Giallo Yellow BLU Blue Rosso RED TAB.1 Characteristics Nozzles ISORosso RED Marrone Brown TAB.2 Characteristics Nozzles Conical ISOTAB.3-4 Capacity Hand Lances TAB.5-6 Spraying Tables 2500Table of Programmed Maintenance Operation PROBLEMS, Causes and Solutions50 h 300 h TAB a TAB.12A Allowed FittingsTAB.12B Allowed Fittings TAB bIlpolietilene Rotazionale Member of the group